User selection guide (actionmaster specifications) – HP 30 HP30 User Manual
Page 9
i
USER SELECTION GUIDE (ACtionMaster SPECIFICATIONS)
230V Class (1 ~ 30HP)
Model Number
SV xxx ACtionMaster - 2
008
015
022
037
055
075
110
150
185
220
HP
1 2 3 5 7.5 10 15 20 25 30
Motor
Rating
1
kW
0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22
Capacity
2
[kVA] 1.9 3.0 4.5 6.1 9.1 12.2 17.5 22.9 28.2 33.5
FLA
[A]
5 8 12 16 24 32 46 60 74 88
Frequency
0 ~ 400 Hz (0-120Hz for Vector control)
Output
Ratings
Voltage
200 ~ 230 V
3
Voltage
3 Phase, 200 ~ 230 V (
± 10 %)
Input
Ratings
Frequency
50 ~ 60 Hz (
±5 %)
Braking Circuit
On the Board
On the Board
On the Board
(Optional Resistor)
Optional (Braking Unit, Resistor)
4
Average Braking
Torque
100% 100% 150%
150%
Max. Continuous
Baking Time
5 seconds
5 seconds
15 seconds
Controlled by Braking Unit
5
Dynamic
Braking
4
Max. Duty
3 % ED
2 % ED
5 % ED
5 % ED
Weight
[lbs]
10.1 10.1 10.6 10.8 16.5 17.0 30.4 31.5 42.8 44.1
460V Class (1 ~ 30HP)
Model Number
SV xxx ACtionMaster - 4
008
015
022
037
055
075
110
150
185
220
HP
1 2 3 5 7.5
10 15 20 25 30
Motor
Rating
1
kW
0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22
Capacity
2
[kVA]
1.9 3.0 4.5 6.1 9.1 12.2 18.3 22.9 29.7 34.3
FLA
[A]
2.5 4 6 8 12 16 24 30 39 45
Frequency
0 ~ 400 Hz (0-120Hz for Vector control)
Output
Ratings
Voltage
380 ~ 460 V
3
Voltage
3 Phase, 380 ~ 460 V (
± 10 %)
Input
Ratings
Frequency
50 ~ 60 Hz (
±5 %)
Braking Circuit
On the Board
On the Board
On the Board
(Optional Resistor)
Optional (Braking Unit, Resistor)
4
Dynamic
Braking
4
Max. Braking Torque
100%
100%
150%
150%
1
Indicates the maximum applicable capacity when using a 4 Pole motor.
2
Rated capacity (
√ 3*V*I) is based on 220V for 200V class and 440V for 400V class.
3
Maximum output voltage will not be greater than the input voltage. Output voltage less than the input voltage may be programmed.
4
1~5 HP inverters have internal braking resistors as standard. 7.5~10 HP inverters utilize optional braking resistors.