7 application group [app – HP 30 HP30 User Manual
Page 79
Chapter 5 - Parameter List
5-19
Keypad Display
Setting Range
Code
Description
LCD
7-Segment
LCD
7-Segment
Units
Factory
Default
Adj.
During
Run
Page
101 3
70 0
71 1
110 2
COM-13 Device Net Input Instance In Instance
13
111 3
- 70 No
COM-17
PLC Option Station
Number
Station ID
17
0 to 63
1
1
Yes
COM-20 Profibus ID
Profi MAC ID
20
0 to 127
1
1
Yes
COM-30 Output Number
Output Num
30
0 to 8
1
3
Yes
COM-31 Output 1
Output 1
31
0000-57FF(HEX)
000A(HEX) Yes
COM-32 Output 2
Output 2
32
0000-57FF(HEX)
000E(HEX) Yes
COM-33 Output 3
Output 3
33
0000-57FF(HEX)
000F(HEX) Yes
COM-34 Output 4
Output 4
34
0000-57FF(HEX)
0000(HEX)
Yes
COM-35 Output 5
Output 5
35
0000-57FF(HEX)
0000(HEX)
Yes
COM-36 Output 6
Output 6
36
0000-57FF(HEX)
0000(HEX)
Yes
COM-37 Output 7
Output 7
37
0000-57FF(HEX)
0000(HEX)
Yes
COM-38 Output 8
Output 8
38
0000-57FF(HEX)
0000(HEX)
Yes
COM-40 Input Number
Input Num
40
0 to 8
1
2
Yes
COM-41 Input 1
Input 1
41
0000-57FF(HEX)
0005(HEX)
Yes
COM-42 Input 2
Input 2
42
0000-57FF(HEX)
0006(HEX)
Yes
COM-43 Input 3
Input 3
43
0000-57FF(HEX)
0000(HEX)
Yes
COM-44 Input 4
Input 4
44
0000-57FF(HEX)
0000(HEX)
Yes
COM-45 Input 5
Input 5
45
0000-57FF(HEX)
0000(HEX)
Yes
COM-46 Input 6
Input 6
46
0000-57FF(HEX)
0000(HEX)
Yes
COM-47 Input 7
Input 7
47
0000-57FF(HEX)
0000(HEX)
Yes
COM-48 Input 8
Input 8
48
0000-57FF(HEX)
0000(HEX)
Yes
COM-52 ModBus Option Selection ModBus Mode
52
ModBus RTU
ModBus
RTU
Yes
COM-99 Return Code
Not
displayed
99
Not available
[PROG/ENT]
or
[SHIFT/ESC]
- 1 Yes
5.7 Application Group [APP]
Keypad Display
Setting Range
Code
Description
LCD
7-Segment
LCD
7-Segment
Units
Factory
Default
Adj.
During
Run
Page
APP-00 Jump to Desired Code #
Jump code
Not displayed
0 to 99
Not available
1
1
Yes
6-2
None 0
Traverse 1
MMC 2
APP-01
Application Mode
Selection
App Mode
01
DRAW 3
- None No