Chapter 6 - Parameter description [FU1]

6-20

Note: The set value is the percentage of FU2-33 [Rated

Motor Current].


FU1-59 [Stall Prevention Mode Selection]

Setting Range

3

rd

bit 2

nd

bit 1

st

bit

FU1-59 Description

0 0 1 001

Stall Prevention during
Acceleration

0 1 0 010

Stall Prevention during Steady
Speed

1 0 0 100

Stall Prevention during

Deceleration

When FU1-59 is set to ‘111’, stall prevention works during
accelerating, steady speed and decelerating.


Note: The acceleration and deceleration time may take

longer than the time set in DRV-01, DRV-02 when Stall
Prevention is selected.

Note: If stall prevention status persists, inverter may stop

during acceleration.













[Stall Prevention during Acceleration]


























[Stall Prevention during Steady Speed]













[Stall Prevention during Deceleration]


FU1-99: Return Code (7-Segment Keypad)







This code is used to exit a group when using a 7-segment
keypad. After pressing

PROG/ENT

key, set the value to ‘1’

and press the

PROG/ENT

key again to exit.






Related Functions: FU2-33 [Rated Motor Current]

Output Current

Time

Output Frequency

Time

FU1-60

[Stall level]

FU1-60

[Stall Level]

Output Current

Time

Output Frequency

Time

FU1-60

[Stall Level]

FU1-60

[Stall Level]

Time

DC Link Voltage

Time

Output Frequency

390VDC or

680V DC

0

99

Factory Default:

0

Related Functions: FU2-99 [Return Code]

I/O-99 [Return Code]

EXT-99 [Return Code]

COM-99 [Return Code]