beautypg.com

HP 30 HP30 User Manual

Page 67

background image

Chapter 5 - Parameter List

5-7

Keypad Display

Setting Range

Code

Description

LCD

7-Segment

LCD

7-Segment

Units

Factory

Default

Adj.

During

Run

Page

FU2-27

Delay Time
Before Auto Restart

Retry Delay

27

0 to 60 [sec]

0.1

1.0 [sec]

Yes

6-2

FU2-28 Speed Search Hold Time

SS blk time

28

0 to 60 [sec]

0.1

1.0 [sec]

No

6-2

0.75kW 0

1.5kW 1
2.2kW 2
3.7kW 3
5.5kW 4
7.5kW 5

11.0kW 6
15.0kW 7
18.5kW 8

FU2-30 Rated Motor Selection

Motor select

30

22.0kW 9

-

18

No

FU2-31 Number of Motor Poles

Pole number

31

2 to 12

1

4

No

FU2-32 Rated Motor Slip

Rated-Slip

32

0 t o10 [Hz]

0.01

No

FU2-33

Rated Motor Current
(RMS)

Rated-Curr

33

1 to 200 [A]

1

No

FU2-34

No Load Motor Current
(RMS)

Noload-Curr

34

0.5 to 200 [A]

1

No

FU2-36 Motor Efficiency

Efficiency

36

70 to 100 [%]

1

19

No

FU2-37 Load Inertia

Inertia rate

37

0 to 1

1

0

No

6-2

FU2-38 Carrier Frequency

Carrier freq

38

1 to 15 [kHz]

1

5 [kHz]

Yes

6-2

V/F 0

Slip comp

1

Sensorless_S 2
Sensorless_T 3

Vector_SPD 4

FU2-39 Control Mode Selection

Control mode

40

Vector_TRQ 5

- V/F No

6-2

No 0

All 1

Rs + Lsigma

Enc Test

FU2-40 Auto Tuning

Auto tuning

41

Tr

- No No

FU2-41

20

Stator Resistance of
Motor

Rs

42

0 to (depending on FU2-30) [ohm] 0.001

No

FU2-42

Leakage Inductance of
Motor

Lsigma

44

0 to (depending on FU2-30) [mH] 0.001

21

No

6-2

18

The rated motor is automatically set according to the inverter model name. If different, set the motor capacity connected.

19

This value is automatically entered according to the rated motor set in FU2-30. If different, set the correct value of the motor.

20

Code FU2-41 through FU2-46 appears only when FU2-39 is set to ‘Sensorless_X’ or ‘Vector_XXX’.

21

This value is automatically entered according to the rated motor set in FU2-30. If different, set the correct value of the motor.