Application

Parameter Code

When you want to use the auto tuning function

FU2-41 ~ 44

When you want to operate using PID feedback

FU2-50 ~ 54

When you want to change the reference frequency for acceleration and deceleration

FU2-70

When you want to change the acceleration and deceleration time scale

FU2-71

When you want to set the initial keypad display that is displayed when the power is turned ON

FU2-72

When you want to set the user defined display

FU2-73

When you want to adjust the gain for the motor RPM display

FU2-74

When you want to set the dynamic braking (DB) resistor mode

FU2-75 ~ 76

When you want to verify the inverter software version

FU2-79

When you want to change the connection from one motor to the other motor which use difference parameters

FU2-81 ~ 90

When you want to copy the inverter parameter to another inverter

FU2-91 ~ 92

When you want to initialize the parameters

FU2-93

When you want to prevent the parameters from being changed

FU2-94

I/O Group

When you want to set the analog voltage or current for the frequency reference

I/O-01 ~ 10

When you want to set the operating method when the frequency reference is lost

I/O-11

When you want to change the functions for the input terminals P1, P2, and P3

I/O-12 ~ 14

When you want to check the status of the input/output terminals

I/O-15 ~ 16

When you want to change the response time of the input terminals

I/O-17

When you want to use the JOG and multi step speed operation

I/O-20 ~ 24

When you want to change the 1

st

~ 7

th

acceleration/deceleration time

I/O-25 ~ 38

When you want to use the FM meter terminal output

I/O-40 ~ 41

When you want to set the frequency detection level

I/O-42 ~ 43

When you want to change the functions of the multi function auxiliary contact output (AXA-AXC)

I/O-44

When you want to exchange the motor to commercial power line from inverter or the opposite

I/O-44

When you want to use the fault relay (30A, 30B, 30C) functions

I/O-45

When you want to use RS232/485 communication

I/O-46 ~ 47

When you want to set the operating method when the frequency reference is lost

I/O-48 ~ 49

When you want to use the auto (sequence) operation

I/O-50 ~ 84

EXT Group (When a Sub-board and/or an option board is installed)

When you want to define the functions for the input terminals P4, P5, P6 (SUB-A, SUB-C)

EXT-02 ~ 04

When you want to use the analog voltage (V2) input (SUB-A, SUB-C)

EXT-05 ~ 10

When you want to use the encoder pulse for feedback to control the motor speed, or use the pulse input for
frequency reference (SUB-B)

EXT-14 ~ 24

When you want to change the functions of the output terminals Q1, Q2, Q3 (SUB-A, SUB-C)

EXT-30 ~ 32

When you want to use the LM meter terminal output (SUB-A, SUB-C)

EXT-34 ~ 35

When you want to use the analog outputs (AM1, AM2 terminals)

EXT-40 ~ 43