HP 30 HP30 User Manual
Page 73

Chapter 5 - Parameter List
5-13
Keypad Display
Setting Range
Code
Description
LCD
7-Segment
LCD
7-Segment
Units
Factory
Default
Adj.
During
Run
Page
Seq pulse
19
Ready 20
Trv. ACC
21
Trv. DEC
22
MMC 23
Zspd Dect
24
Torq Dect
25
I/O-45
Fault Output Relay Setting
(30A, 30B, 30C)
Relay mode
45
000 to 111
(Bit Set)
- 010 Yes
6-2
I/O-46
25
Inverter Number
Inv No.
46
1 to 31
1
1
Yes
6-2
1200 bps
0
2400 bps
1
4800 bps
2
9600 bps
3
I/O-47 Baud Rate
Baud rate
47
19200 bps
4
- 9600
bps Yes 6-2
None 0
FreeRun 1
I/O-48
Operating selection at
Loss of Freq. Reference
Lost command
48
Stop 2
- None Yes
I/O-49
Waiting Time after Loss of
Freq. Reference
Time out
49
0.1 to 120 [sec]
0.1
1.0 [sec]
Yes
6-2
None 0
Auto-A 1
I/O-50
Auto (Sequence)
Operation selection
Auto mode
50
Auto-B 2
- None No
I/O-51
Sequence Number
Selection
Seq select
51
1 to 5
1
1
Yes
I/O-52
The Number of Steps of
Sequence Number #
Step number
52
1 to 8
1
2
Yes
6-2
I/O-53
26
1
st
Step Frequency of
Sequence 1
Seq1 / 1F
53
0.01 to FU1-20
0.01 11.00 [Hz]
Yes
I/O-54
Transient Time to 1
st
Step
of Sequence 1
Seq1 / 1T
54
0.1 to 6000 [sec]
0.1
1.1 [sec]
Yes
I/O-55
Steady Speed Time at 1
st
Step of Sequence 1
Seq1 / 1S
55
0.1 to 6000 [sec]
0.1
1.1 [sec]
Yes
Reverse 0
I/O-56
Motor Direction of 1
st
Step
of Sequence 1
Seq1 / 1D
56
Forward 1
- Forward Yes
I/O-57
1
st
Step Frequency of
Sequence 2
Seq1 / 2F
57
0.01 to FU1-20
0.01 21.00 [Hz]
Yes
6-2
25
Code I/O-46 through I/O-49 are used in Option Board like RS485, Device, Net and F-net etc.
26
The ‘Seq#’ of code I/O-53 through I/O-60 varies according to the sequence number selected in I/O-51.
The parameter code may be extended to I/O-84 depending the number of steps set in I/O-52 because the steps can be set up to 8.