HP 30 HP30 User Manual
Page 130
Chapter 6 - Parameter Description [I/O]
6-38
Step
Frequency
Parameter
Code
Speed-H
(P3)
Speed-M
(P2)
Speed-L
(P1)
Step
Freq-0
DRV-00
0 0 0
Step
Freq-1
DRV-05
0 0 1
Step
Freq-2
DRV-06
0 1 0
Step
Freq-3
DRV-07
0 1 1
Step
Freq-4
I/O-21
1 0 0
Step
Freq-5
I/O-22
1 0 1
Step
Freq-6
I/O-23
1 1 0
Step
Freq-7
I/O-24
1 1 1
0: OFF, 1: ON
☞
I/O-20 [Jog Frequency] can be used as one of the step
frequencies.
☞
If the ‘Jog’ terminal is ON, inverter operates to Jog
frequency regardless of other terminal inputs
.
[Multi-Step Frequency Operation]
☞
Note: The frequency for ‘Speed 0’ is determined by DRV-04.
[XCEL-L, XCEL-M, XCEL-H]
By setting P1, P2 and P3 terminals to ‘XCEL-L’, ‘XCEL-M’
and ‘XCEL-H’ respectively, up to 8 different Accel and
Decel times can be used. The Accel/Decel time is set in
DRV-01 ~ DRV-02 and I/O-25 ~ I/O-38.
The Accel/Decel time is determined by the combination of
P1, P2 and P3 terminals as shown in the following table.
Accel/Decel
Time
Parameter
Code
XCEL-H
(P3)
XCEL-M
(P2)
XCEL-L
(P1)
Accel Time-0
DRV-01
Decel Time-0
DRV-02
0 0 0
Accel Time-1
I/O-25
Decel Time-1
I/O-26
0 0 1
Accel Time-2
I/O-27
Decel Time-2
I/O-28
0 1 0
Accel Time-3
I/O-29
Decel Time-3
I/O-30
0 1 1
Accel Time-4
I/O-31
Decel Time-4
I/O-32
1 0 0
Accel Time-5
I/O-34
Decel Time-5
I/O-35
1 0 1
Accel Time-6
I/O-36
Decel Time-6
I/O-37
1 1 0
Accel Time-7
I/O-38
Decel Time-7
I/O-39
1 1 1
0: OFF, 1: ON
[Multi-Accel/Decel Time Operation]
P1-CM
ON
ON
Output Frequency
Time
Time
P2-CM
ON
ON
Time
P3-CM
ON
Time
JOG-CM
ON
Time
FX-CM
ON
Time
RX-CM
ON
Time
ON
ON
Step
0
Step
1
Step
2
Step
3
Step
4
Step
5
Step
6
Step
7
Jog
Related Functions: DRV-05 ~ DRV-07 [Step Frequency]
I/O-20 [Jog Frequency]
I/O-20 ~ I/O-24 [Step Frequency]
P1-CM
ON
Output Frequency
Time
Time
P2-CM
ON
Time
P3-CM
ON
Time
FX-CM
ON
Time
ON
ON
ON
ON
Ref.
Freq.
Time 0 Time 1 Time 2 Time 3 Time 4 Time 5 Time 6 Time 7
Related Functions: I/O-25 ~ I/O-38 [1
st
~7
th
Accel/Decel Time]