APPENDIX B - PARAMETERS BASED ON APPLICATION

Application

Parameter Code

DRV Group

When you want to change the frequency setting

DRV-00

When you want to change the acceleration and deceleration time of the motor

DRV-01, DRV-02

When you want to change the run/stop method

DRV-03

When you want to change the frequency reference source

DRV-04

When you want to set the multi-function

DRV-005 ~ 07

When you want to see the output current, motor speed and the DC link voltage of inverter

DRV-08 ~ 10

When you want to see the output voltage, output power, output torque from the user display

DRV-11

When you want to check the fault of the inverter

DRV-12

FU1 Group

When you want to use the Jump Code

FU1-00

When you want to prevent the motor from rotating at opposite directions

FU1-03

When you want to select the acceleration and deceleration pattern suitable for your application

FU1-05 ~ 06

When you want to change the stopping method

FU1-07

When you want to change the stopping accuracy for steady stop

FU1-08 ~ 11

When DC injection braking is required before starting

FU1-12 ~ 13

When you want to set the maximum frequency and the base frequency according to the rated torque of the
motor

FU1-20 ~ 21

When you want to adjust the starting frequency

FU1-22

When you want to limit the mechanical rotating speed to a fixed value

FU1-23 ~ 25

When a large starting torque is needed for loads such as elevators (Manual/Auto Torque Boost)

FU1-26 ~ 28

When you want to select an appropriate output characteristic (V/F characteristic) according to loads

FU1-29

When you want to se up your own V/F pattern

FU1-30 ~ 37

When you want to adjust the output voltage of the inverter

FU1-38

When you want to use the energy saving function

FU1-39

When you want to protect the motor from overheating

FU1-50 ~ 53

When you want to output a signal when the overload condition lasts more than a fixed amount of time

FU1-54 ~ 55

When you want to cut off the output when the overload condition lasts more than a fixed amount of time

FU1-56 ~ 58

When you want to set the stall prevention function

FU1-59 ~ 60

FU2 Group

When you want to check the fault history of the inverter

FU2-01 ~ 06

When you want to use dwell function

FU2-07 ~ 08

When you want to prevent the resonance from the oscillating characteristics of a machine

FU2-10 ~ 16

When you want to protect inverter from input/output phase loss

FU2-19

When you want to start the inverter as soon as the power is turned ON

FU2-20

When you want to restart the inverter by resetting the fault when a fault occur

FU2-21

When you want to use the instant power failure restart function (Speed Search)

FU2-22 ~ 25

When you want to use the retry function

FU2-26 ~ 27

When you want to enter the motor constants

FU2-30 ~ 37

When you want to reduce noise or leakage current by changing the PWM carrier frequency

FU2-39

When you want to change the control method (V/F, slip compensation, PID, or sensorless operation)

FU2-40