Avago Technologies MegaRAID SAS 9240-4i User Manual
Page 75

LSI Corporation
- 75 -
StorCLI Reference Manual
January 2013
Appendix B: MegaCLI Commands to StorCLI Command Conversion
Table 23 Alarm Commands
Description
MegaCLI Command
StorCLI Command
Show alarm properties.
MegaCli -AdpGetProp AlarmDsply
-aN|-a0,1,2|-aALL
storcli /cx(x|all) show alarm
Set alarm properties.
MegaCli -AdpSetProp AlarmEnbl |
AlarmDsbl | AlarmSilence
-aN|-a0,1,2|-aALL
storcli /cx(x|all) set
alarm=
Table 24 Event Log Properties Commands
Description
MegaCLI Command
StorCLI Command
Show event logs.
MegaCli -AdpEventLog
-GetEventLogInfo
-aN|-a0,1,2|-aALL
storcli /cx show eventloginfo
Show the specified type of event
logs.
MegaCli -AdpEventLog -GetEvents
{-info -warning -critical
-fatal} {-f <fileName>}
-aN|-a0,1,2|-aALL
storcli /cx show events [[type=
vd=<0,1,...>] filter=
Show the specified event logs.
MegaCli -AdpEventLog
-GetSinceShutdown {-info
-warning -critical -fatal}
{-f <fileName>}
-aN|-a0,1,2|-aALL
storcli /cx show events
[type=[latest=x|ccincon
vd=|[sincereboot|sinceshutdown|included
eleted|latest|ccincon]]]
[filter=[info|warning|critical|fatal]]
file=xyz.txt
Delete the event logs.
MegaCli -AdpEventLog -Clear
-aN|-a0,1,2|-aALL
storcli /cx delete events
Table 25 Premium Feature Key Commands
Description
MegaCLI Command
StorCLI Command
Show the Safe ID of the controller.
MegaCli -ELF -GetSafeId -a0
storcli /cx(x|all) show safeid
Show the Advanced Software
Options that are enabled on the
controller, including the ones in trial
mode.
MegaCli -ELF –ControllerFeatures
-a0
storcli /cx(x|all) show all
NOTE This information shows as part of the controller
show all.
Apply the Activation Key in preview
mode.
MegaCli -ELF -Applykey key –val
-preview -a0
storcli /cx(x|all) set aso key=<key
value> preview
Apply the Activation Key.
MegaCli -ELF -Applykey key –val
-a0
storcli /cx(x|all) set aso key=<key
value>
Deactivate the trial key.
MegaCli -ELF
–DeactivateTrialKey -a0
storcli /cx(x|all) set aso
deactivatetrialkey
Show the re-host information and, if
re-hosting is necessary, show the
controller and key vault serial
numbers.
MegaCli -ELF -ReHostInfo -a0
storcli /cx(x|all) show rehostinfo
Indicate to the controller that the
re-host is complete.
MegaCli -ELF -ReHostComplete -a0
storcli /cx(x|all) set aso
rehostcomplete
- MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-24i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID SAS 9285-8ecv