2 controller show commands, Controller show commands – Avago Technologies MegaRAID SAS 9240-4i User Manual
Page 15

LSI Corporation
- 15 -
StorCLI Reference Manual
January 2013
Chapter 4: Working with the Storage Command Line Tool
Controller Commands
4.2.2
Controller Show Commands
The Storage Command Line Tool supports the following show commands:
storcli /cx show
storcli /cx show all
storcli /cx show freespace
The detailed description for each command follows.
storcli /cx show
This command shows the summary of the controller information. The summary includes basic controller information,
foreign configurations, drive groups, virtual drives, physical drives, enclosures, and BBU information.
Input example:
storcli /c1 show
perfmode
0
: Tuned to provide best IOPS, currently
applicable to non-FastPath
1
: Tuned to provide least latency, currently
applicable to non-FastPath
Performance tuning setting for the controller.
pi
on|off
Enables/disables data protection on the controller.
preventpiimport
on|off
Enables/disables import data protection drives on
the controller.
prcorrectunconfiguredareas
on|off
Correct media errors during PR by writing 0s to
unconfigured areas of the disk.
prrate
0 to 100
Sets patrol read rate of the virtual drives in percentage.
rebuildrate
0 to 100
Sets rebuild rate of the drive in percentage.
reconrate
0 to 100
Sets reconstruction rate for a drive in percentage.
restorehotspare
on|off
Becomes a hot spare on insertion of a failed drive.
smartpollinterval
0 to 65535
Set time for polling of SMART errors in seconds.
spinupdrivecount
0 to 255
Sets number of drives that are spun up at a time.
spinupdelay
0 to 255
Sets spin-up delay between a group of drives or a set of
drives, in seconds.
stoponerror
on|off
Stops the MegaRAID BIOS during POST, if any errors are
encountered.
time
Valid time in yymmdd hh:mm:ss format or
systemtime
Sets the controller time to your input value or the system
time (local time in 24-hour format).
usefdeonlyencrypt
on|off
Enables/disables FDE drive-based encryption.
Table 4 Properties for Show and Set Commands (Continued)
Property Name
Set Command Range
Description
- MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-24i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID SAS 9285-8ecv