beautypg.com

Avago Technologies MegaRAID SAS 9240-4i User Manual

Page 44

background image

LSI Corporation

- 44 -

StorCLI Reference Manual

January 2013

Chapter 4: Working with the Storage Command Line Tool

Dimmer Switch Commands

storcli /cx/vx set ds=<default | auto | none | max | maxnocache>

This command changes the power-saving properties on a virtual drive. See dimmerswitch in the following table
for values.

Input example:

storcli /cx/vx set ds=default

You can use the following combinations for the dimmer switch commands:

storcli /cx set ds=off type=1|2|3|4

storcli /cx set ds=on type=1|2 [properties]

storcli /cx set ds=on type=3|4 defaultldtype= [properties]

storcli /cx set ds=on [properties]

The following table describes the power-saving options.

storcli/cx show DimmerSwitch(ds)

This command shows the current dimmer switch setting for the controller.

Input example:

storcli/c0 show ds

NOTE Only the ds3 dimmer switch option cannot be selected in the Storage Command Line Tool.

Table 18 Dimmer Switch Input Options

Option

Value Range

Description

dimmerswitch

or ds

on|off

Turns the dimmer switch option on.

type

1

: Unconfigured

2

: Hot spare

3

: Virtual drive

4

: All

Specifies the type of drives that the dimmer switch
feature is applicable. By default, it is activated for
unconfigured drives, hot spare drives and virtual drives.

defaultldtype

auto

: Logical device power savings are managed

by the firmware.

none

: No power saving policy.

max

: Logical device uses maximum power savings.

maxnocache

: Logical device does not cache write

to maximise power savings.

Specifies the default logical drive type that is created by
the dimmer switch option; set to none automatically.

properties

disableldps

: Interval in hours or time in hh:mm

format

spinupdrivecount

: Valid enclosure number (0

to 255)

SpinUpEncDelay

: Valid time in seconds

Sets the interval or time in which the power-saving
policy for the logical drive is turned off.

Specifies the number of drives in the enclosure that are
spun up.

Specifies the delay of spin-up groups within an enclosure
in seconds.