StorCLI Reference Manual
January 2013
Appendix B: MegaCLI Commands to StorCLI Command Conversion
Table 16 Battery Commands
Description
MegaCLI Command
StorCLI Command
Show battery-related information.
MegaCli -AdpBbuCmd -aN|-a0,1,2|-aALL storcli /cx/bbu show
storcli /cx/bbu show all
Show the battery learn properties.
MegaCli -AdpBbuCmd -GetBbuProperties
-aN|-a0,1,2|-aALL
storcli /cx/bbu show properties
Show the battery information,
firmware status, and the gas gauge
status.
MegaCli -AdpBbuCmd -GetBbuStatus
-aN|-a0,1,2|-aALL
storcli /cx/bbu show status
Show battery capacity information.
MegaCli -AdpBbuCmd
-GetBbuCapacityInfo
-aN|-a0,1,2|-aALL
storcli /cx/bbu show all
Show battery design information.
MegaCli -AdpBbuCmd -GetBbuDesignInfo
-aN|-a0,1,2|-aALL
storcli /cx/bbu show all
Set battery properties
MegaCli -AdpBbuCmd -SetBbuProperties
-f <fileName> -aN|-a0,1,2|-aALL
storcli /cx/bbu set
learnDelayInterval=<value>
storcli /cx/bbu set bbuMode=
storcli /cx bbu set
autolearnmode=<value>
,
where x= 0 – Enabled, 1 – Disabled, 2 – Warn though
event.
Start battery learn cycle.
MegaCli -AdpBbuCmd -BbuLearn
-aN|-a0,1,2|-aALL
storcli /cx/bbu start learn
Set the battery to low power storage
mode.
MegaCli -AdpBbuCmd -BbuMfgSleep
-aN|-a0,1,2|-aALL
storcli /cx/bbu set powermode=sleep
Seal the gas gauge EEPROM write
access
MegaCli -AdpBbuCmd -BbuMfgSeal
-aN|-a0,1,2|-aALL
storcli /cx/bbu set
writeaccess=sealed
- MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-24i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID SAS 9285-8ecv