8 virtual drive migration commands – Avago Technologies MegaRAID SAS 9240-4i User Manual
Page 37
LSI Corporation
- 37 -
StorCLI Reference Manual
January 2013
Chapter 4: Working with the Storage Command Line Tool
Virtual Drives Commands
4.4.8
Virtual Drive Migration Commands
The Storage Command Line Tool supports the following commands for virtual drive migration (reconstruction):
storcli /cx/vx show migrate
storcli /cx/vx start migrate
[option=
The detailed description for each command follows.
storcli /cx/vx show migrate
This command shows the progress of the virtual drive migrate operation in percentage.
Input example:
storcli /c0/v0 show migrate
storcli /cx/vx start migrate
This command starts the reconstruction on a virtual drive to the specified RAID level by adding or removing disks
from the existing virtual drive. You can use the following options with the start migrate command:
Virtual drive migration can be done between the following RAID levels.
NOTE The virtual drive migration commands are not supported in Embedded MegaRAID.
Table 16 Virtual Drive Migration Command Options
Options
Value Range
Description
type = RAID level
RAID [0|1|5|6]
The RAID level to which the virtual drive must be
migrated.
[option=
disk=
add
: Adds disks to the virtual drive and starts
reconstruction.
remove
: Removes disks from the virtual drive and starts
reconstruction.
disk
: The enclosure number and the slot number of the
disks to be added to the virtual drive.
Adds or removes disks from the virtual drive.
Table 17 Virtual Drive Migration Table
Initial RAID level
Migrated RAID level
RAID 0
RAID 1
RAID 0
RAID 5
RAID 0
RAID 6
RAID 1
RAID 0
RAID 1
RAID 5
RAID 1
RAID 6
RAID 5
RAID 0
RAID 5
RAID 6
RAID 6
RAID 0
RAID 6
RAID 5
- MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-24i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID SAS 9285-8ecv