3 controller background tasks operation commands, 1 rebuild rate – Avago Technologies MegaRAID SAS 9240-4i User Manual
Page 16

LSI Corporation
- 16 -
StorCLI Reference Manual
January 2013
Chapter 4: Working with the Storage Command Line Tool
Controller Commands
storcli /cx show all
This command shows all controller information, which includes basic controller information, bus information,
controller status, advanced software options, controller policies, controller defaults, controller capabilities, scheduled
tasks, miscellaneous properties, foreign configurations, drive groups, virtual drives, physical drives, enclosures, and
BBU information.
Input example:
storcli /c0 show all
storcli /cx show freespace
This command shows the usable free space in the controller.
Input example:
storcli /c0 show freespace
4.2.3
Controller Background Tasks Operation Commands
4.2.3.1
Rebuild Rate
storcli /cx set rebuildrate=
storcli /cx show rebuildrate
The detailed description for each command follows.
storcli /cx set rebuildrate=<value>
This command sets the rebuild task rate of the specified controller. The input value is in percentage.
Input example:
storcli /c0 set rebuildrate=30
storcli /cx show rebuildrate
This command shows the current rebuild task rate of the specified controller in percentage.
Input example:
storcli /c0 show rebuildrate
NOTE The PCI information displayed as a part of storcli /cx show and storcli /cx show all
commands is not applicable for the FreeBSD operating system. Hence, the PCI information fields are displayed
as N/A.
NOTE A high rebuild rate slows down I/O processing.
- MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-24i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID SAS 9285-8ecv