Avago Technologies MegaRAID SAS 9240-4i User Manual

Page 46

background image

LSI Corporation

- 46 -

StorCLI Reference Manual

January 2013

Chapter 4: Working with the Storage Command Line Tool

BBU Commands

storcli /cx/bbu set learndelayinterval=<value>

This command sets the learn delay interval for the BBU in hours. The value must be between 0 to 168 hours (7 days).

Input example:

storcli /c0/bbu set learnDelayInterval=30

storcli /cx/bbu set powermode=sleep

This command places the battery in low-power storage mode. The battery automatically exits this state after
5 seconds.

Input example:

storcli /c0/bbu set powermode=sleep

storcli /cx/bbu set writeaccess=sealed

This command seals the gas gauge EEPROM write access.

Input example:

storcli /c0/bbu set writeaccess=sealed

storcli /cx/bbu show modes

This command shows the bbu mode information that includes the bbu mode number, retention time, service life,
maximum temperature, and battery learn information.

Input example:

storcli /c0/bbu show modes

storcli /cx/bbu show properties

This command shows the BBU Learn properties for a controller.

Input example:

storcli /c0/bbu show properties

storcli /cx/bbu show status

This command shows the battery information, firmware status, and the gas gauge status.

Input example:

storcli /c0/bbu show status

storcli /cx/bbu start learn

This command starts the BBU learning cycle. The battery learn cycle is immediately started and no other parameters
are required for this command.

Input example:

storcli /c0/bbu start learn

NOTE Use the set writeaccess=sealed command at manufacturing time.