Avago Technologies MegaRAID SAS 9240-4i User Manual
Page 73

LSI Corporation
- 73 -
StorCLI Reference Manual
January 2013
Appendix B: MegaCLI Commands to StorCLI Command Conversion
Set the drive state to offline.
MegaCli –PDOffline
-PhysDrv[E0:S0,E1:S1....]
-aN|-a0,1,2|-aALL
storcli /cx/ex/sx set offline
Set the drive state to JBOD
MegaCli –PDMakeGood
-PhysDrv[E0:S0,E1:S1....]
-aN|-a0,1,2|-aALL
storcli /cx/ex/sx set good [force]
Set the drive state to JBOD
MegaCli -PDMakeJBOD
-PhysDrv[E0:S0,E1:S1,...]
-aN|-a0,1,2|-aALL
storcli /cx/ex/sx set jbod
Add and delete hot spare drives.
MegaCli –PDHSP {–Set
[{-Dedicated -ArrayN |
-Array0,1...}] [-EnclAffinity]
[-nonRevertible] } |
-Rmv -PhysDrv[E0:S0,E1:S1,...]
-aN|-a0,1,2|-aALL
storcli /cx/ex/sx add hotsparedrive
[dgs=
nonrevertible
storcli /cx/ex/sx delete hotsparedrive
Start, stop, pause, resume or show
the progress of an initialization
process.
MegaCli –PDClear -Start |-Stop|
-ShowProg |-ProgDsply
- PhysDrv[E0:S0,E1:S1....]
-aN|-a0,1,2|-aALL
storcli /cx/ex/sx start initialization
storcli /cx/ex/sx stop initialization
storcli /cx/ex/sx pause initialization
storcli /cx/ex/sx resume initialization
storcli /cx/ex/sx show initialization
Start a drive locate and activate the
drive’s LED or stop a drive locate and
deactivate the drive’s LED.
MegaCli –PDLocate {[-start] |
-stop} -physdrv[E0:S0,E1:S1,...]
-aN|-a0,1,2|-aALL
storcli /cx/ex/sx start locate
storcli /cx/ex/sx stop locate
Spin down an unconfigured drive
and prepare it for removal or spin up
spun-down drive and mark the drive
state as unconfigured good.
MegaCli –PDPrpRmv [-Undo]
– PhysDrv[E0:S0,E1:S1....]
-aN|-a0,1,2|-aALL
storcli /cx/ex/sx spindown
storcli /cx/ex/sx spinup.
Show physical drive information of all
connected drives.
MegaCli –PDList
-aN|-a0,1..|-aAll
storcli /cx/eall/sall show [all]
NOTE This command does not show drives whose
enclosure device ID is not available.
Flash the physical drive firmware.
MegaCLI PdFwDownload[offline]
[ForceActivate] {[-SataBridge]
-PhysDrv[0:1]}|{-EncdevId[devId1
]} -f <filename>
-aN|-a0,1,2|-Aall
storcli /cx[/ex]/sx download
src=<filepath> [satabridge]
storcli /cx/ex download src=<filepath>
[forceActivate]
Erase the drive's security
configuration and securely erase data
on a drive.
MegaCli -PDInstantSecureErase
-PhysDrv[E0:S0,E1:S1,...] |
[-Force] -aN|-a0,1,2|-aALL
storcli /cx/ex/sx secureerase [force]
Table 20 Physical Drive Commands (Continued)
Description
MegaCLI Command
StorCLI Command
- MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-24i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID SAS 9285-8ecv