beautypg.com

7 drive group commands, 1 drive group show, 8 dimmer switch commands – Avago Technologies MegaRAID SAS 9240-4i User Manual

Page 43: 1 change virtual drive power settings commands, Dimmer switch, Commands, Dimmer switch commands

background image

LSI Corporation

- 43 -

StorCLI Reference Manual

January 2013

Chapter 4: Working with the Storage Command Line Tool

Drive Group Commands

storcli/cx/vx show bootdrive

This command shows the boot drive for the controller. The boot drive can be a physical drive or a virtual drive.

Input example:

storcli /c0/v0 show bootdrive

4.7

Drive Group Commands

This section describes the drive group commands.

4.7.1

Drive Group Show

The Storage Command Line Tool supports the following drive group commands:

storcli /cx/dall show

storcli /cx/dall show all

storcli /cx/dall show cachecade

storcli /cx/dall show

This command shows the topology information of the drive group.

Input example:

storcli /c0/dall show

storcli /cx/dall show all

This command shows all available configurations in the controller which includes topology information, virtual drive
information, physical drive information, free space, and free slot information.

Input example:

storcli /c0/dall show all

storcli /cx/dall show cachecade

This command shows all CacheCade virtual drive information.

Input example:

storcli /c0/dall show cachecade

4.8

Dimmer Switch Commands

4.8.1

Change Virtual Drive Power Settings Commands

The Storage Command Line Tool supports the following command to change the Dimmer Switch® setting. The
Dimmer Switch is the power-saving policy for the virtual drive.