7 drive group commands, 1 drive group show, 8 dimmer switch commands – Avago Technologies MegaRAID SAS 9240-4i User Manual
Page 43: 1 change virtual drive power settings commands, Dimmer switch, Commands, Dimmer switch commands

LSI Corporation
- 43 -
StorCLI Reference Manual
January 2013
Chapter 4: Working with the Storage Command Line Tool
Drive Group Commands
storcli/cx/vx show bootdrive
This command shows the boot drive for the controller. The boot drive can be a physical drive or a virtual drive.
Input example:
storcli /c0/v0 show bootdrive
4.7
Drive Group Commands
This section describes the drive group commands.
4.7.1
Drive Group Show
The Storage Command Line Tool supports the following drive group commands:
storcli /cx/dall show
storcli /cx/dall show all
storcli /cx/dall show cachecade
storcli /cx/dall show
This command shows the topology information of the drive group.
Input example:
storcli /c0/dall show
storcli /cx/dall show all
This command shows all available configurations in the controller which includes topology information, virtual drive
information, physical drive information, free space, and free slot information.
Input example:
storcli /c0/dall show all
storcli /cx/dall show cachecade
This command shows all CacheCade virtual drive information.
Input example:
storcli /c0/dall show cachecade
4.8
Dimmer Switch Commands
4.8.1
Change Virtual Drive Power Settings Commands
The Storage Command Line Tool supports the following command to change the Dimmer Switch® setting. The
Dimmer Switch is the power-saving policy for the virtual drive.
- MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-24i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID SAS 9285-8ecv