Avago Technologies MegaRAID SAS 9240-4i User Manual
Page 69

LSI Corporation
- 69 -
StorCLI Reference Manual
January 2013
Appendix B: MegaCLI Commands to StorCLI Command Conversion
Table 17 RAID Configuration Commands
Create a RAID configuration of RAID
type 0, 1, 5, and 6.
MegaCli –CfgLDAdd
-R0|-R1|-R5|-R6[E0:S0,E1:S1,...]
[WT | WB] [NORA | RA | ADRA]
[Direct | Cached]
[CachedBadBBU|NoCachedBadBBU]
[-szXXXXXXXX [-szYYYYYYYY [... ]]]
[-strpszM] [–Hsp[E5:S5,...]]
[–afterLdX] -aN
storcli /cx add vd
type=raid[0|1|5|6]
[Size=<VD1_Sz>,<VD2_Sz>,..|*all]
[name=<VDNAME1>,..]
drives=e:s|e:s-x|e:s-x,y;e:s-x,y,z
[PDperArray=x]
[SED] [pdcache=on|off|*default][pi]
[DimmerSwitch(ds)=default|automatic
(auto)|*none|maximum(max)
|MaximumWithoutCaching(maxnocache)]
[wt|*wb] [nora|*ra] [*direct|cached]
[CachedBadBBU|*NoCachedBadBBU]
[strip=<8|16|32|64|128|256|512|1024
] [AfterVd=X]
[Spares=[e:]s|[e:]s-x|[e:]s-x,y]
[force]
Create a CacheCade virtual drive.
MegaCLI -CfgCacheCadeAdd [-rX]
-Physdrv[E0:S0,...] {-Name
LdNamestring} [WT|WB|ForcedWB]
[-assign -LX|L0,2,5..|LALL]
-aN|-a0,1,2|-Aall
storcli /cx add vd cachecade|cc
Type=[0,1,10]
drives=[e:]s|[e:]s-x|[e:]s-x,y
[ < WT| WB> ] [assignvds=0,1,2]
Create a RAID configuration of RAID
type 10, 50, and 60.
MegaCli –CfgSpanAdd
-aN|-a0,1,2|-aALL
-R10|-R50|R60
–Array0[E0:S0,E1:S1,...]
–Array1[E0:S0,E1:S1,...] [...]
[WT | WB] [NORA | RA | ADRA]
[Direct | Cached]
[CachedBadBBU|NoCachedBadBBU]
[-szXXXXXXXX [-szYYYYYYYY [... ]]]
[-strpszM] [–afterLdX] -aN
storcli /cx add vd
type=raid[10|50|60]
[Size=<VD1_Sz>,<VD2_Sz>,..|*all]
[name=<VDNAME1>,..]
drives=e:s|e:s-x|e:s-x,y;e:s-x,y,z
[PDperArray=x]
[SED] [pdcache=on|off|*default][pi]
[DimmerSwitch(ds)=default|automatic
(auto)|*none|maximum(max)
|MaximumWithoutCaching(maxnocache)]
[wt|*wb] [nora|*ra] [*direct|cached]
[CachedBadBBU|*NoCachedBadBBU]
[strip=<8|16|32|64|128|256|512|1024
] [AfterVd=X]
[Spares=[e:]s|[e:]s-x|[e:]s-x,y]
[force]
Delete a virtual drive.
MegaCli -CfgClr [-Force]
-aN|-a0,1,2|-aALL
storcli /cx/vall delete
Show the topology information of
the drive group.
MegaCLI -CfgDsply
-aN|-a0,1,2|-Aall
storcli /cx/dall show [all]
Show information for a CacheCade
virtual drive.
MegaCLI -CfgCacheCadeDsply
-aN|-a0,1,2|-Aall
storcli /cx/dall show CacheCade(cc)
- MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-24i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID SAS 9285-8ecv