Avago Technologies MegaRAID SAS 9240-4i User Manual
Page 59

LSI Corporation
- 59 -
StorCLI Reference Manual
January 2013
Appendix A: 3Ware CLI Commands to StorCLI Command Conversion
Show cache and access policies of the
virtual drive.
/cx/ux show [all]
/cx/ux show autoverify
/cx/ux show cache
/cx/ux show identify
/cx/ux show ignoreECC
/cx/ux show name
/cx/ux show parit
/cx/ux show qpolicy
/cx/ux show rapidrecovery
/cx/ux show rdcache
/cx/ux show rebuildstatus
/cx/ux show serial
/cx/ux show status initializestatus
/cx/ux show storsave
/cx/ux show verifystatus
/cx/ux show volumes
/cx/ux show wrcache
/cx/vx show all
NOTE The StorCLI does not have commands to
show individual virtual drive properties.
Start initialization (writing 0s) on the
virtual drive.
/cx/ux start verify
NOTE Only the bios can do a foreground
initialization. A background initialization does
otherwise. A verify starts a back ground initialization.
/cx/vx start init [Full]
Stop an ongoing initialization on the
virtual drive.
/cx/ux stop verify
NOTE Only the bios can do a foreground
initialization. A background initialization does
otherwise. A verify starts a back ground initialization
/cx/vx stop init
Show a snapshot of the ongoing
initialization, if any.
/cx/ux show [all]
NOTE Only the bios can do a foreground
initialization. A background initialization does
otherwise. A verify starts a back ground initialization.
/cx/vx show init
Start a consistency check on the
virtual drive.
/cx/ux start verify
/cx/vx start cc
Stop a consistency check on the
virtual drive.
/cx/ux stop verify
/cx/vx stop cc
Reconstruct the selected virtual disk
to a new RAID level.
/cx/ux migrate type=<RaidType>
[disk=<p:-p..>] [strip=<size>]
[noscan] [nocache] [autoverify]
[group=<3|4|5|6|7|8|9|10|11|12|13|1
4|15|16>]
RaidType={ raid0, raid1, raid5,
raid10, raid50, single, raid6 }
/cx/vx start migrate
/cx/vx show migrate
Change the power-saving setting on
the virtual drive.
/cx/ux set powersavestandbytimer=<5
to 999>
/cx/vx set ds=
Table 6 Virtual Drive Commands (Continued)
Description
3Ware CLI Command
StorCLI Command
- MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-24i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID SAS 9285-8ecv