Operating Instructions Powador XP100-HV
Page 87
U s e r i n t e r f a c e
9.4.2 PT
1000
Figure 87: PT 1000
Figure 88: Wiring of the PT 1000
9.4.3 Wind
speed
Figure 89: Wind speed
Figure 90: Confi guration of the Wind speed
Terminal number
Terminal designation
Specifi cation
Wire cross- section
3a
PTN
0 to 10 V
AWG 24
(0.205 mm
2
)
3b
PTP
4a
RSVN
0 to 10 V
4b
RSVP
Table 28: Connections for analogue user input - PT 1000
9.4.4
Parameter settings for analogue sensors
In order to determine measured values using the analogue sensors, you have to set the “Options” parameter.
The options are calculated and set by a service technician from KACO new energy GmbH.
ATTENTION
Be careful not to destroy the sensor's measuring input!
Avoid using voltages > 10 V and make sure that the polarity is correct.
1b
1b
1a
UAI
2a
2a
2b
2b
3a
3a
3b
3b
4a
4a
4b
4b
Si-12TC
bk
bn
Red (rd)
Black (bk)
Brown (bn)
VCC (12 to 24 Vdc)
GND
Cell Temperature (0 to 10 V)
12 ... 24 Vdc
+
-
rd
Red (rd)
Black (bk)
Brown (bn)
VCC (12 to 24 Vdc)
GND
Wind speed (0 to 10 V)