Operating Instructions Powador XP100-HV

P a r a m e t e r

Parameters

Units

Ranges

Descriptions

Default

Power Meter

kWh

0 ~ 99999999

PV generated power check

0

RS485 Protocol

-

0 ~ 999

RS485 communications’ protocol

0: ACI protocol

1: Communication with prolog

2: Communication with PVI-go

0

RS485 ID

-

0 ~ 3

ID for RS485 communication

0

CAN ID

-

0 ~ 999

ID for CAN communication

0

Argus Box 1 Address -

0 ~ 99999

Argus Box 1 address and type setup

0

Argus Box 2 Address -

0 ~ 99999

Argus Box 2 address and type setup

0

Argus Box 3 Address -

0 ~ 99999

Argus Box 3 address and type setup

0

Argus Box 4 Address -

0 ~ 99999

Argus Box 4 address and type setup

0

Argus Box 5 Address -

0 ~ 99999

Argus Box 5 address and type setup

0

Argus Box 6 Address -

0 ~ 99999

Argus Box 6 address and type setup

0

Argus Box 7 Address -

0 ~ 99999

Argus Box 7 address and type setup

0

Argus Box 8 Address -

0 ~ 99999

Argus Box 8 address and type setup

0

Prolog Positive
Sequence Enable

-

0 ~ 1

Provide positive sequence for grid voltage as
prolog

0

Prolog Expanded
Total Yield

-

0 ~ 1

Provide expanded total yield to Prolog

0

Table 15: Digital Parameters

8.6 Analog

Parameters

Parameters

Units

Ranges

Descriptions

Default

AI1 Off set

N/A

-300 ~ 300

AI (Analog Input) 1 off set

0

AI1 Gain

N/A

-300 ~ 300

AI (Analog Input) 1 gain

120

AI2 Off set

N/A

-300 ~ 300

AI (Analog Input) 2 off set

20

AI2 Gain

N/A

-300 ~ 300

AI (Analog Input) 2 gain

10.87

AI3 Off set

N/A

-300 ~ 300

AI (Analog Input) 3 off set

50

AI3 Gain

N/A

-300 ~ 300

AI (Analog Input) 3 gain

10

AI4 Off set

N/A

-300 ~ 300

AI (Analog Input) 4 off set

0

AI4 Gain

N/A

-300 ~ 300

AI (Analog Input) 4 gain

6

Table 16: Analog Parameters