Control Signals

4.1.1 Connecting Sequence Input Signals

4 -2

4.1 Sequence Input Signals

This section provides information on the connections, functions, displays, and meaning of the sequence input

signals.

4.1.1 Connecting Sequence Input Signals

The connections of sequence input signals vary between stand-alone drives and NC systems as described

below.

J

M5A for Stand-alone Drives

Connect sequence input signals to the 6CN connector of the I/O card.
The sequence input signals can be input to the 6CN connector as 0 V, 24 V, or external common input sig-

nals. Refer to 3.4.4 Sequence Input Signal Circuits for details.

J

M5N for NC Systems

The Inverter performs serial transmission of sequence input signals with NC machines over YENET1200

communications. Refer to the manual for the NC machine for sequence input signals and input addresses.

4.1.2 Selecting Sequence Input Signals

Some functions of sequence input signals are selected by settings constants. Set the constants as shown

in the following table for the desired functions.

Table 4.1

Sequence Input Signals

No.

6CN

Pin No.

Signal

Function

Related Constants

1

5

DAS

*

Speed reference digital/analog selection

2

6

RDY

Operation ready

RDY selected at C1-37 bit 2

= 0.

EMG2

Emergency stop 2

EMG2 selected at C1-37 bit

2 = 1.

3

7

EMG

Emergency stop

4

8

FWD

Forward run

5

9

REV

Reverse run

6

10

TLH

Torque limit H

TLH selected at C1-36 bit 2

= 0.

7

11

TLL

Torque limit L

TLL selected at C1-36 bit 1,

0 = 00.

INC

Incremental

INC selected at C1-36 bit 1,

0 = 10.

8

12

SSC

Soft start cancel

SSC selected at C1-36 bit 3

= 0.

SV

Servo mode

SV selected at C1-36 bit 3 =

1.

9

13

RST

*

Error reset

10

14

CHW

Winding selection

11

15

PPI

P control/PI control selection

PPI selected at C1-36 bit 4 =

0.

LM10

*

Load factor meter 10x selection signal

LM10 selected at C1-36 bit

4 = 1

12

16

ORT

Orientation

13

17

LGR

L gear selection

14

18

MGR

M gear selection

* The M5N for NC systems does not use the RST signal.