Yaskawa Varispeed 626M5 User Manual
Page 237

14.2 Standard Motor Specifications
14 -33
Rated Output kW
Shaft Dimensions
30
min.
Rating
Continuous
Rating
Q
QK
QR
S
T
U
W
d
m
3.7
*1
2.2
60
(2.36)
45
(1.77)
1
(0.039)
+0.009
−0.004
28
7
(0.28)
4
(0.16)
8
(0.31)
16
(0.63)
M6
5.5
3.7
60
(2.36)
45
(1.77)
1
(0.039)
0
−0.013
28
7
(0.28)
4
(0.16)
8
(0.31)
22
(0.87)
M4
7.5
5.5
80
(3.15)
70
(2.76)
1
(0.039)
0
−0.016
32
8
(0.31)
5
(0.2)
10
(0.39)
22
(0.87)
M5
11
7.5
110
(4.33)
90
(3.54)
0.5
(0.02)
0
−0.016
48
9
(0.35)
5.5
(0.22)
14
(0.55)
40
(1.57)
M5
15
11
110
(4.33)
90
(3.54)
1
(0.039)
0
−0.016
48
9
(0.35)
5.5
(0.22)
14
(0.55)
40
(1.57)
M5
18.5
15
110
(4.33)
90
(3.54)
1
(0.039)
0
−0.016
48
9
(0.35)
5.5
(0.22)
14
(0.55)
40
(1.57)
M5
22
18.5
110
(4.33)
90
(3.54)
1
(0.039)
+0.030
+0.011
55
10
(0.39)
6
(0.24)
16
(0.63)
45
(1.77)
M5
30
22
140
(5.51)
110
(4.33)
2
(0.079)
+0.030
+0.011
60
11
(0.43)
7
(0.28)
18
(0.71)
50
(1.97)
M6
37
30
140
(5.51)
110
(4.33)
2
(0.079)
+0.030
+0.011
60
11
(0.43)
7
(0.28)
18
(0.71)
50
(1.97)
M6
45
*2
37
140
(5.51)
110
(4.33)
1
(0.039)
+0.030
+0.011
70
12
(0.47)
7.5
(0.3)
20
(0.79)
60
(2.36)
M6
* 1. 3.7/2.2 kW is 15 min. rating (50% ED)/Continuous rating. There are no eyebolts on the 3.7/2.2 kW or 5.5/3.7 kW models.
* 2. 45/37 kW is for the 400 V Series.
Notes:1. The shaft key and the key way are standard JIS B 1301-1996 models.
2. External dimensions are the same for both the 200 V and 400 V Series.
14