beautypg.com

2 standard connection diagram – Yaskawa Varispeed 626M5 User Manual

Page 137

background image

8.2 Standard Connection Diagram

8 -3

8.2 Standard Connection Diagram

Figure 8.2 shows the standard connections to use a motor encoder signal with the load shaft and motor shaft

linked in a 1:1 configuration. Figure 8.3 shows the standard connections to use the load shaft encoder signal.

In both cases, the example shows an stand-alone drive (CIMR-M5Ajjjj).

5CN

51CN

VS−626M5

3CN

52CN

2CN

+5V

0V

4,5,6

1,2,3

THSA

THSB

SS

8

7

9

1
2

3

4

5

6

7

8
9

11

12

10

PG

TS

P

PA

:

PA

PB

:

PB

PC

:

PC

16

17

18

19

14
15

P

P

P

PAO

:

PAO

PBO

:

PBO

PCO

:

PCO

13

14

15

16

11

12

P

P

P

17

1CN

TLL(INC)

SSC(SV)

19,20,21

22,23

24,25

EXTCOM0

*

2

24VCOM

0VCOM

6CN

6
7

8

9

10

11

12

RDY

EMG

FWD

REV

TLH

13
14

5

15
16

17

18

RST
CHW

DAS

PPI
ORT

LGR

MGR

3

4

2

33
34

35

SCOM

0V

SS

ZSPD

36

37

38
39

40

46

30

TDET

TLE

ORG
ORE

CHWE

TALM

COM2

SDET

AGR

42 COM1

43
44
45

FLT

26
27

28
29

FC0

FC1

FC2
FC3

41 FLTL

BCD

BIN

1

1

2

2

4

4

8

8

1

2

4

8

P1
N1

P1

N1

3MCCB

R
S
T

1MCCB 1MC

L

P/

N/

VS−656MR5

R/L1
S/L2
T/L3

r

t

2MCCB 2MC

A1/r
A2/t

1CN

P/

N/

U
V

IM

BCD BIN

1

1

2

2

4

4

8

8

10

20

40

80

100
200

400

800

10
20
40

80

16

32

64

128

256
512

1024

2048

10

20

40

80

100
200

400

16

32

64

128
256

512

1024

19

20
21

22

23

24

25

26
27

28
29

30

D1

D2
D3

D4

D5

D6

D7

D8
D9

D10

D11

D12

EXTCOM

*

2

24VCOM

0VCOM

31

32

33

6CN

47

48

49

50

SM

0V

0V

LM

SM

LM

P

W

Z1

Z2

Z3

U/T1
V/T2

W/T3

SS

3-phase

200

VAC

*

1

1-phase

300 VAC

Ground to 100 Ω or less.

Not used

MCCB: Wiring circuit breaker

MC: Magnetic contactor

L: AC reactor

24-V external

power supply

*

3

P1N1 power

supply cable

Special bus bar

*1

In the 400-V class, 3-phase 400 VAC is used.

*2

6CN EXTCOM0 and 1CN EXTCOM are isolated internally.

*3

Sequence input common is the external common contact.

indicates shielded twisted-pair cable.

I/O card

*

3

24-V external

power supply

12-bit digital refer-

ence

Stop position

reference

Motor encoder signal output

3-digit 2-digit

3-digit

Sign Sign

Ground to 100 Ω or less.

3-phase

200

VAC

*

1

Motor

Cooling fan

Flat cable

Not used

Digital Op-

erator (op-

tional)

Speed reference

Fig 8.3

Standard Connection Diagram for 200-V Class User-set Position Stop Control

Using a Motor Encoder

8