beautypg.com

6 fault display mode – Yaskawa Varispeed 626M5 User Manual

Page 105

background image

Operating the Digital Operator

5.3.6 Fault Display Mode

5 -10

5.3.6 Fault Display Mode

If a protective function is activated because of a fault, the fault code is displayed. Up to six faults are re-

corded to view the order of a series of faults.

Time

Fault Reset

01 occurred

(Overcur-

rent)

31 occurred

(Motor Overspeed)

d2 occurred

(CPU built-in A/D error)

Display Example

D

Displays the second fault No.

D

Displays the first fault No.

D

Displays the third fault No.

Notes on resetting faults

S

To reset a fault by the Digital Operator after removing the cause, press [RESET] key in fault display

mode. In other modes, [RESET] key cannot reset the fault.

S

Before resetting, turn OFF the run command signals (FWD, REV, ORT) that are externally input.

The reset operation will not be possible if a run command signal is ON.

5

IMPORTANT

This manual is related to the following products: