Yaskawa Varispeed 626M5 User Manual
Page 118
Trial Operation
6.4.9 Motor Code Selection (MTR: C1-25)
6 -12
Precautions when Changing the Motor Code
After changing the Motor code, be sure to turn OFF the control power supply. Next, check that the Digital
Operator display is no longer lit, and then turn ON the power supply again. This operation will enable the new
Motor code.
Table 6.4
Motor Codes for Standard Spindle Motors
Voltage
Class
Motor
Inverter
Capacity
Inverter
Capacity
Selection
(C1-56)
Motor Model
Motor
Code
(C1-25)
Motor Max.
Speed
(min
−1
)
30 min./
Continuous
Rated Out-
put (kW)
Load Fac-
tor Meter
Max. Value
(%)
200 V
Standard
23P7
04
UAASKA-04FZj
001
8,000
3.7/2.2
202
25P5
05
UAASKA-06FZj
002
8,000
5.5/3.7
178
27P5
06
UAASKA-08FZj
003
8,000
7.5/5.5
164
2011
07
UAASKA-11FZj
004
6,000
11/7.5
176
2015
08
UAASKA-15FZj
005
6,000
15/11
164
2018
09
UAASKA-19FZj
006
6,000
18.5/15
148
2022
0A
UAASKA-22FZj
007
6,000
22/18.5
143
2030
0B
UAASKJ-30FZj
008
4,500
30/22
164
2037
0C
UAASKJ-37FZj
009
4,500
37/30
148
Winding
selection
25P5
05
UAASKB-06FZj
062
6,000 (1,500)
5.5/3.7
178
selection
27P5
06
UAASKB-08FZj
063
6,000 (1,500)
7.5/5.5
164
2011
07
UAASKB-11FZj
064
6,000 (1,500)
11/7.5
176
2015
08
UAASKB-15FZj
065
4,800 (1,000)
15/11
164
2018
09
UAASKB-19FZj
066
4,800 (1,000)
18.5/15
148
2022
0A
UAASKB-22FZj
067
4,800 (1,000)
22/18.5
143
2030
0B
UAASKB-30FZj
068
4,800 (1,000)
30/20
180
400 V
Standard
45P5
25
UAASKA-06FZjOOE
102
8,000
5.5/3.7
178
47P5
26
UAASKA-08FZjOOE
103
8,000
7.5/5.5
164
4011
27
UAASKA-11FZjOOE
104
6,000
11/7.5
176
4015
28
UAASKA-15FZjOOE
105
6,000
15/11
164
4018
29
UAASKA-19FZjOOE
106
6,000
18.5/15
148
4022
2A
UAASKA-22FZjOOE
107
6,000
22/18.5
143
4030
2B
UAASKJ-30FZjOOE
108
4,500
30/22
164
4037
2C
UAASKJ-37FZjOOE
109
4,500
37/30
148
4045
2D
UAASKJ-45FZjOOE
10A
4,500
45/37
146
Winding
selection
45P5
25
UAASKB-06FZjOOE
162
6,000 (1,500)
5.5/3.7
178
selection
47P5
26
UAASKB-08FZjOOE
163
6,000 (1,500)
7.5/5.5
164
4011
27
UAASKB-11FZjOOE
164
6,000 (1,500)
11/7.5
176
4015
28
UAASKB-15FZjOOE
165
4,800 (1,000)
15/11
164
4018
29
UAASKB-19FZjOOE
166
4,800 (1,000)
18.5/15
148
4022
2A
UAASKB-22FZjOOE
167
4,800 (1,000)
22/18.5
143
4030
2B
UAASKB-30FZjOOE
168
4,800 (1,000)
30/20
180
Note: Values in parentheses are the maximum speed (min
−1
) of the low-speed windings.
The maximum value of the load factor meter = (30-min rated output x 120%)/(continuous rated output) (%)
6
IMPORTANT