10.1 User Constants

10-5

Table 10.1

User Constants (continued)

Con-

stant

No.

Name

Explanation

Change

*

1

Unit Standard

Setting

Upper

Limit/

Lower

Limit

C1-38

Signal Selec-

tions 3

SEL3

*

4

Signal selections for control mode and level

S

Bits 1 and 0: Load meter filter selection

*

2

00: 2-ms filter

01: 10-ms filter

10: 100-ms filter

11: 500-ms filter

S

Bit 2: Torque limit auto judgement

0: Speed reference gain switching OFF

1: Speed reference gain switching ON

S

Bit 3: Sensitivity switching selection when using servo mode

*

2

0: Not judged

1: Judged

S

Bit 4: Excessive speed deviation protection (AL-32) operation threshold

0: 1/2 or less of speed reference

1: 1/4 or less of speed reference

S

Bit 5: Speed limiting level

*

2

0: 105% of rated reference

1: 110% of rated reference

S

Bit 6: Speed agree signal (AGR) output at zero speed

0: Output (AGR: closed)

1: Not output (AGR: open)

S

Bit 7: Load meter adjustment selection

*

2

0: 120% of rated output signal for 30 min.

1: 100% of continuous rated output signal

No

---

00000000

---

C1-39

Signal Selec-

tions 4

SEL4

*

4

Signal selections for control mode and level

S

Bit 0: Orientation control method

0: Encoder

1: Magnetic sensor

When the setting has changed, turn the control power supply OFF then

ON again.

No

---

00000000

---

C1-40

Signal Selec-

tions 5

SEL5

*

4

Control mode signal selections

S

Bit 1 and 0: Operation delay time for excessive speed deviation protec-

tion (AL-32)

00: 0 s

01: 0.3 s

10: 0.4 s 11: 0.5 s

S

Bit 2: Torque detection signal (TDET) output

0: Standard output

1: ON for acceleration/deceleration

S

Bit 3: NC orientation

0: Disabled.
1: Enabled. Even if orientation signal (ORT) is input, the

Inverter will not perform orientation. The rotating

direction of motor is determined according to the polar-

ity of speed reference.

S

Bit 4: Load meter output standard selection

*

2

0: Continuous rated output

1: 30 min. rated output

S

Bit 5: Servo mode speed reference gain selection (Enabled when bit 3 of

C1-38 is ON.)

*

2

0: Analog speed reference, 10 V/5,000 rotations/min.
1: Set the read gain of the analog speed reference using

C1-49 or C1-50.

S

Bit 7: Load fault detection selection (AL-33)

0: Disabled

1: Enabled

No

---

00000000

---