Yaskawa Varispeed 626M5 User Manual
Page 208
Specifications
14.1.1 Standard Drive Series
14 -4
Table 14.2 Standard 400 V Series
Model UAAS
FZ***E
A-06
A-08
A-11
A-15
A-19
A-22
J-30
J-37
J-45
Rated
Output
*
1
30-minute Rating (S2)
50%ED Rating (S3)
7.5
(5.5)
10
(7.5)
15
(11)
20
(15)
25
(18.5)
30
(22)
40
(30)
50
(37)
60
(45)
1
HP
(kW)
Continuous Rating
(S1)
5
(3.7)
7.5
(5.5)
10
(7.5)
15
(11)
20
(15)
25
(18.5)
30
(22)
40
(30)
50
(37)
Rated
speed
Base Speed
1500
1150
speed
(min
−1
)
Maximum Speed
8000
6000
4500
Output Torque at Base
N·m
23.5
35.0
47.7
70.0
95.0
117.6
182.3
249.0
306.8
Motor
Output Torque at Base
Speed Continuous Rat-
ing
lb·ft
(kgf·m)
17.4
(2.40)
25.8
(3.57)
35.8
(4.87)
51.7
(7.14)
70.6
(9.74)
86.9
(12.0)
134
(18.6)
183.7
(25.4)
226.4
(31.3)
Rotor Inertia J (GD
2
/4)
lb·ft
2
(kg·m
2
)
0.411
(0.0173)
0.617
(0.026)
0.759
(0.032)
1.614
(0.068)
1.970
(0.083)
2.326
(0.098)
6.122
(0.258)
8.068
(0.340)
11.22
(0.473)
Overload Capacity
120%, 60s of 30-minute rating
Vibration
(µ·m)
V5
V10
Noise Level
75dB (A) or less
80dB (A) or less
Ambient Temperature, Humidity
0°C to 40°C (32°F to 104°F), 95% or less (non-condensing)
Approx. Mass
lb
(kg)
119
(54)
130
(59)
150
(68)
207
(94)
238
(108)
269
(122)
481
(218)
580
(263)
783
(355)
Model CIMR-M5j
*
2
45P5
47P5
4011
4015
4018
4022
4030
4037
4045
Continuous Rated Input Current
(A)
8.8
13.1
17.9
26.2
35.7
44.1
52.4
71.4
88.2
Continuous Rated Output Current
(A)
10.4
15.5
20
28
40
49
56.5
80
98
Control Method
Sine wave PWM Inverter (Vector control)
ter
Speed Control Range
40 min
−1
to maximum motor speed
vert
e
Speed Regulation
0.2% maximum speed or less
In
v
Overload Capacity
*3
120%, 60s of 30-minute rating
Approx. Mass
lb (kg)
11 (5)
27 (12)
35 (16)
Dimensions in inches
Width
3.94 (100)
5.91 (150)
9.84 (250)
Dimensions in inches
(mm)
*4
Height
13.78 (350)
(mm)
*4
Depth
12.60 (320)
Model CIMR-MR5j
*
2
45P5
47P5
4011
4015
4018
4022
4030
4037
4045
Required Power Capacity (kVA)
9
12
19
24
30
36
48
60
70
Continuous Rated Input Current
(A)
6.7
9.85
13.4
19.7
26.8
33.1
39.3
53.6
66.2
troller
Continuous Rated Output Current
(A)
8.8
13.1
17.9
26.2
35.7
44.1
52.4
71.4
88.2
Cont
r
Power Supply
Three-phase, 400 VAC (50/60Hz); 440 VAC (50/60Hz); 460 VAC (60Hz)
(Allowable voltage fluctuation: +10% to −15%, allowable frequency fluctuation: ±5%,
Line-to-line voltage unbalance: 5% or less)
onverter
*5
Control Power Supply
Single-phase, 200 VAC (50/60Hz); 220 VAC (50/60Hz); 230 VAC (60Hz)
(Allowable voltage fluctuation: +10% to −15%, allowable frequency fluctuation: ±5%)
Required power capacity: 100 VA (for independent drive system)
250 VA (for NC system)
Co
Control Method
Power regenerative control (120_ current conduction)
Overload Capacity
120% for one minute, 200% for one second
Approx. Mass
lb (kg)
11 (5)
27 (12)
46 (21)
Dimensions in inches
Width
3.94 (100)
5.91 (150)
9.84 (250)
Dimensions in inches
(mm)
*4
Height
13.78 (350)
(mm)
*4
Depth
12.60 (320)
Power Supply AC Reactor Code
No.
X002501 X010099 X010100 X010101 X010102
X010103 X010104 X010105 X010106
14