background image

5.2 Display Mode Configuration

5 -5

5.2 Display Mode Configuration

The following figure shows the displays of the Digital Operator. Whenever the DSPL (display selection) key

is pressed, the display mode will change.

Control power ON

All LEDs light (for 1.5 s).

*

PROM version No. is displayed (for 0.5 s).

U1-01 (motor speed) data is displayed.

The operating status is displayed.

The control constants are displayed.

C1-37 (bits 1 and 0) turned ON.

The Digital Operator operation

reference is displayed.

Alarm is ON.

The alarm number is displayed.

The alarm log is displayed.

Alarm is ON.

Uj-jj

Cj-jj

d1-jj

AL-jj

j

ALjj

*

“88888” will be display if the model is the M5N for NC systems until communications with

the NC machine are established.

Fig 5.4

Display Order of Digital Operator