beautypg.com

Yaskawa Varispeed 626M5 User Manual

Page 192

background image

12 - 8

Table 12.2

Inverter Faults (continued)

Fault No.

Name

Contents

Corrective Actions

Error Code

Tuneup
incomplete
(magnetic
sensor meth-
od orienta-
tion)

Orientation command was input be-
fore tuning up (minor fault).

Perform orientation tuneup.

Ffff

Magnetic sen-
sor signal
detection er-
ror

Incorrect magnetic sensor signal
voltage level during tuning up.

S

Check the wiring of magnetic

sensor signal lines.

S

Replace the magnetic sensor or

magnetizer.

Ffff

Fault of num-
ber of pulses
per rotation
(magnetic
sensor meth-
od orienta-
tion)

Number of motor pulses per main
axis rotation (4096 ÷ speed gear ra-
tio) exceeded ±6% during tuning
up.

S

Check control constants C1-27,

28, 29.

S

Check the wiring of motor en-

coder signal lines.

Ffff

Magnetic sen-
sor signal dis-
connection

Magnetic sensor signal cable was
disconnected or connected improp-
erly.

S

Check the wiring of magnetic

sensor signal lines.

S

Replace the magnetic sensor or

magnetizer.

S

Perform tuneup again.

Ffff

INC signal er-
ror
(Magnetic
sensor meth-
od orienta-
tion)

INC signal input timing error
(minor fault)

After carrying out absolute posi-
tioning, change circuit to com-
mand INC signal.

Ffff

YENET1200
communica-
tion error

Communication error between YE-
NET1200 card and NC machine.

Check the wiring on communica-
tion line.

---

Excessive
position devi-
ation

Position deviation exceeded the al-
lowable range.

Check the main axis load.

---

YENET1200
card ROM er-
ror

YENET1200 card memory (PROM)
error

Replace YENET1200 card.

---

YENET1200
communica-
tion WDT er-
ror 1

WDT error between YENET1200
card and NC machine.

Check the wiring on communica-
tion line.

---

YENET1200
communica-
tion WDT er-
ror 2

WDT error between YENET1200
card and control PCB.

Replace the control PCB.

---

YENET1200
card NMI

YENET1200 card detected NMI.

Replace YENET1200 card.

---

YENET1200
card zero di-
vision

YENET1200 card detected division/
overflow error.

---

Communica-
tions timeout
1

Answer to communications com-
mand between YENET1200 card
and control PCB does not return.

Replace the controller PCB.

---

12

Troubleshooting

This manual is related to the following products: