Yaskawa Varispeed 626M5 User Manual

Page 173

background image

Control Constants

10-6

Con-

stant

No.

Upper

Limit/

Lower

Limit

Standard

Setting

Unit

Change

*

1

Explanation

Name

C1-41

to

Internal Speed

Reference Set

Values

SPD1 to SPD8

Set values when using internal speed references using digital speed refer-

ences. The correspondence with reference inputs (1CN) are as shown

below, and are given as percentages over the rated speed (C1-26).
Pin 19: SPD1

Pin 23: SPD5

No

%

0 00

100.00

to

C1-48

*

2

SPD1 to SPD8

Pin 19: SPD1

Pin 23: SPD5

Pin 20: SPD2

Pin 24: SPD6

Pin 21: SPD3

Pin 25: SPD7

Pin 22: SPD4

Pin 26: SPD8

No

%

0.00

0.00

C1-49

to

Servo Mode

Speed Refer-

ence Gain

SVGAIN1 and

SVGAIN2

Set value of the analog speed reference read gain in servo mode. (En-

abled when C1-38 bit 3 is ON and C1-40 bit 5 is ON.) Set the ratio of the

number of rotations when the analog speed reference is 10 V over the

rated speed (C1-26).

A l

d f

10 V/(S100 SVGAIN/100) i

1

No

%

100 00

100.00

to

C1-50

*

2

SVGAIN2

Analog speed reference 10 V/(S100 x SVGAIN/100) min

−1

.

Select C1-49 and C1-50 using the DAS signal (C6N-5).

DAS = OFF: C1-49 (SVGAIN1)

DAS = ON: C1-50 (SVGAIN2)

No

%

100.00

0.00

C1-51

to

C1-53

---

---

---

---

---

---

C1 54

*

2

Speedmeter Sig-

nal Offset Ad-

Offset adjustment value for speedometer signal. Outputs speedometer

signal after subtracting from SM

OFS.

Yes

5.4

0

200

C1-54

*

2

nal Offset Ad

justment Value

SM

OFS

signal after subtracting from SM

OFS.

Yes

5.4

mV

0

−200

C1 55

*

2

Load Meter Sig-

nal Offset Ad-

Offset adjustment value for load meter signal. Outputs speedometer

signal after subtracting from LM

OFS.

Yes

5.4

0

200

C1-55

*

2

nal Offset Ad

justment Value

LM

OFS

signal after subtracting from LM

OFS.

Yes

5.4

mV

0

−200

C1-56

Inverter Capac-

ity Selection

UNITNO

Inverter capacity setting. (The setting is already made at factory prior

to shipment.)

4045

45P5

25

47P5

26

4011

27

4018 4022 4030

2B

4037

2C

4015

28

29 2A

2D

2037

CIMR

−M5

23P7

04

25P5

05

27P5

06

2015 2018 2022

0A

2030

0B

2011

07

08 09

0C

CIMR

−M5

When the setting has changed, turn the control power supply OFF for

3 seconds or longer then ON again.

200 V class

400 V class

Set value

Set value

No

---

---

---

C1-57

Signal Selec-

tions 6

SEL6

*

4

Control mode signal selections

S

Bit 0: Fault record clear selection

0: Disabled

1: Clears next time control power is turned ON.

(Automatically returns to 0.)

S

Bit 4 and 5: Emergency stop fault (AL-21) detection time selection

*

5

00: 10 sec

01: 20 sec

10: 40 sec

11: Disabled

No

---

00000000

---

C1-58

Signal Selec-

tions 7

SEL7

*

4

Control mode signal selections

S

Bit 0: YENET1200 card encoder selection

0: Motor encoder (2CN)

1: Load shaft encoder (8CN)

When the setting has changed, turn the control power supply OFF then

ON again.

No

---

00000000

---

C1-59

---

---

---

---

---

---

10

This manual is related to the following products: