background image

12 -16

Table 12.3

Motor Faults and Corrective Actions (continued)

Fault

Cause

Corrective Action

Orientation signal ORT is not input.

Confirm that orientation signal ORT is closed on operating
status display (U1-09).

Incorrect setting of selection signal
(Completion signal is not output at tuning of initial
setting.)

Set tuneup operation selection signal (C2-22 or C3-22, bit 4)
to “1.”

Orientation completion

Incorrect speed changing ratio setting

Verify the machine data for transmission ratio values (C1-27
to 29).

Orientation completion
signal is not output.

Position control proportional gain is high.

S

Confirm that no vibration occurs in the forward and reverse

directions near the stop position.

S

Lower position control proportional gain to reduce vibration.

Position control proportional gain is low.

S

Confirm that the load shaft has reached the stop position on

operating status display (U2-03 or U3-03).

S

Increase position control proportional gain to reach the com-

manded position.

Fault of Orientation Card or control PCB

Replace the Orientation Card or the control PCB.