Yaskawa Varispeed 626M5 User Manual
Page 212
Specifications
14.1.2 Winding Selection Drive Series
14 -8
Table 14.4 Winding Selection 400 V Series
Model UAASK
FZ***E
B-06
B-08
B-11
B-15
B-19
B-22
B-30
*1
Rated
Output
*2
30-minute Rating (S2)
50%ED Rating (S3)
7.5
(5.5)
10
(7.5)
15
(11)
20
(15)
25
(18.5)
30
(22)
40
(30)
Output
2
HP (kW)
Continuous Rating
(S1)
5
(3.7)
7.5
(5.5)
10
(7.5)
15
(11)
20
(15)
25
(18.5)
27
(20)
Rated
speed
Base Speed
500
400
speed
(min
−1
)
Maximum Speed
6000
4800
Output Torque at Base
N·m
71
105
143
262
358
442
477
Motor
Output Torque at Base
Speed Continuous Rating lb·ft
(kgf·m)
52.3
(7.21)
77.6
(10.7)
105.9
(14.5)
193.6
(26.7)
264.5
(36.5)
326.2
(45.0)
351.8
(48.7)
Rotor Inertia J (GD
2
/4)
lb·ft
2
(kg·m
2
)
1.614
(0.068)
1.970
(0.083)
2.563
(0.108)
6.146
(0.259)
11.22
(0.473)
13.00
(0.548)
13.00
(0.548)
Overload Capacity
120%, 60s of 30-minute rating
Vibration
(µ·m)
V5
V10
Noise Level
75dB (A) or less
80dB (A) or less
Ambient Temperature, Humidity
0°C to 40°C (32°F to 104°F), 95% or less (non-condensing)
Approx. Mass
lb
(kg)
207
(94)
238
(108)
291
(132)
481
(218)
783
(355)
893
(405)
893
(405)
Model CIMR-M5j
*
3
45P5
47P5
4011
4015
4018
4022
4030
Continuous Rated Input Current
(A)
8.8
13.1
17.9
26.2
35.7
44.1
52.4
Continuous Rated Output Current
(A)
10.4
15.5
20
28
40
49
56.5
Control Method
Sine wave PWM Inverter (Vector control)
er
Speed Control Range
40 min
−1
to maximum motor speed
verte
r
Speed Regulation
0.2% maximum speed or less
Inv
e
Overload Capacity
120%, 60s of 30-minute rating
I
Approx. Mass
lb (kg)
11 (5)
27 (12)
35 (16)
Applicable Magnetic Contactor
Model
HV-75AP4
HV-150AP4
Dimensions in inches
Width
3.94 (100)
5.91 (150)
9.84 (250)
Dimensions in inches
(mm)
*4
Height
13.78 (350)
(mm)
*4
Depth
12.60 (320)
r
Model CIMR-MR5j
*
3
45P5
47P5
4011
4015
4018
4022
4030
oller
Required Power Capacity (kVA)
9
12
19
24
30
36
48
Contr
o
Continuous Rated Input Current
(A)
6.7
9.85
13.4
19.7
26.8
33.1
39.3
C
Continuous Rated Output Current
(A)
8.8
13.1
17.9
26.2
35.7
44.1
52.4
5
Power Supply
Three-phase, 400 VAC (50/60Hz); 440 VAC (50/60Hz); 460 VAC (60Hz)
(Allowable voltage fluctuation: +10% to −15%, allowable frequency fluctuation: ±5%,
Line-to-line voltage unbalance: 5% or less)
C
onverter
*5
Control Power Supply
Single-phase, 200 VAC (50/60Hz); 220 VAC (50/60Hz); 230 VAC (60Hz)
(Allowable voltage fluctuation: +10% to −15%, allowable frequency fluctuation: ±5%)
Required power capacity: 100 VA (for independent drive system)
250 VA (for NC system)
C
o
Control Method
Power regenerative control (120_ current conduction)
Overload Capacity
120% for one minute, 200% for one second
Approx. Mass
lb (kg)
11 (5)
27 (12)
46 (21)
Dimensions in inches
Width
3.94 (100)
5.91 (150)
9.84 (250)
Dimensions in inches
(mm)
*4
Height
13.78 (350)
(mm)
*4
Depth
12.60 (320)
Power Supply AC Reactor Code
No.
X002501
X010099
X010100
X010101
X010102
X010103
X010104
14