14.1.2 Winding Selection Drive Series

14 -8

Table 14.4 Winding Selection 400 V Series

Model UAASK

FZ***E

B-06

B-08

B-11

B-15

B-19

B-22

B-30

*1

Rated

Output

*2

30-minute Rating (S2)

50%ED Rating (S3)

7.5

(5.5)

10

(7.5)

15

(11)

20

(15)

25

(18.5)

30

(22)

40

(30)

Output

2

HP (kW)

Continuous Rating

(S1)

5

(3.7)

7.5

(5.5)

10

(7.5)

15

(11)

20

(15)

25

(18.5)

27

(20)

Rated

speed

Base Speed

500

400

speed
(min

−1

)

Maximum Speed

6000

4800

Output Torque at Base

N·m

71

105

143

262

358

442

477

Motor

Output Torque at Base

Speed Continuous Rating lb·ft

(kgf·m)

52.3

(7.21)

77.6

(10.7)

105.9

(14.5)

193.6

(26.7)

264.5

(36.5)

326.2

(45.0)

351.8

(48.7)

Rotor Inertia J (GD

2

/4)

lb·ft

2

(kg·m

2

)

1.614

(0.068)

1.970

(0.083)

2.563

(0.108)

6.146

(0.259)

11.22

(0.473)

13.00

(0.548)

13.00

(0.548)

Overload Capacity

120%, 60s of 30-minute rating

Vibration

(µ·m)

V5

V10

Noise Level

75dB (A) or less

80dB (A) or less

Ambient Temperature, Humidity

0°C to 40°C (32°F to 104°F), 95% or less (non-condensing)

Approx. Mass

lb
(kg)

207

(94)

238

(108)

291

(132)

481

(218)

783

(355)

893

(405)

893

(405)

Model CIMR-M5j

*

3

45P5

47P5

4011

4015

4018

4022

4030

Continuous Rated Input Current

(A)

8.8

13.1

17.9

26.2

35.7

44.1

52.4

Continuous Rated Output Current

(A)

10.4

15.5

20

28

40

49

56.5

Control Method

Sine wave PWM Inverter (Vector control)

er

Speed Control Range

40 min

−1

to maximum motor speed

verte

r

Speed Regulation

0.2% maximum speed or less

Inv

e

Overload Capacity

120%, 60s of 30-minute rating

I

Approx. Mass

lb (kg)

11 (5)

27 (12)

35 (16)

Applicable Magnetic Contactor

Model

HV-75AP4

HV-150AP4

Dimensions in inches

Width

3.94 (100)

5.91 (150)

9.84 (250)

Dimensions in inches
(mm)

*4

Height

13.78 (350)

(mm)

*4

Depth

12.60 (320)

r

Model CIMR-MR5j

*

3

45P5

47P5

4011

4015

4018

4022

4030

oller

Required Power Capacity (kVA)

9

12

19

24

30

36

48

Contr

o

Continuous Rated Input Current

(A)

6.7

9.85

13.4

19.7

26.8

33.1

39.3

C

Continuous Rated Output Current

(A)

8.8

13.1

17.9

26.2

35.7

44.1

52.4

5

Power Supply

Three-phase, 400 VAC (50/60Hz); 440 VAC (50/60Hz); 460 VAC (60Hz)

(Allowable voltage fluctuation: +10% to −15%, allowable frequency fluctuation: ±5%,

Line-to-line voltage unbalance: 5% or less)

C

onverter

*5

Control Power Supply

Single-phase, 200 VAC (50/60Hz); 220 VAC (50/60Hz); 230 VAC (60Hz)

(Allowable voltage fluctuation: +10% to −15%, allowable frequency fluctuation: ±5%)

Required power capacity: 100 VA (for independent drive system)

250 VA (for NC system)

C

o

Control Method

Power regenerative control (120_ current conduction)

Overload Capacity

120% for one minute, 200% for one second

Approx. Mass

lb (kg)

11 (5)

27 (12)

46 (21)

Dimensions in inches

Width

3.94 (100)

5.91 (150)

9.84 (250)

Dimensions in inches
(mm)

*4

Height

13.78 (350)

(mm)

*4

Depth

12.60 (320)

Power Supply AC Reactor Code

No.

X002501

X010099

X010100

X010101

X010102

X010103

X010104

14