beautypg.com

Yaskawa Varispeed 626M5 User Manual

Page 211

background image

14.1 Drives

14 -7

Model CIMR-MR5j

*

2

25P5

27P5

2011

2015

2018

2022

2030

Required Power Capacity (kVA)

9

12

19

24

30

36

48

Continuous Rated Input Current

(A)

13.3

19.7

26.8

39.3

53.6

66.1

78.6

Continuous Rated Output Current

(A)

17.6

26.2

35.7

52.4

71.4

88.1

104.8

Power Supply

Three-phase, 200 VAC (50/60Hz); 220 VAC (50/60Hz); 230 VAC (60Hz)

(Allowable voltage fluctuation: +10% to −15%, allowable frequency fluctuation: ±5%,

Line-to-line voltage unbalance: 5% or less)

C

onverter

*4

Control Power Supply

Single-phase, 200 VAC (50/60Hz); 220 VAC (50/60Hz); 230 VAC (60Hz)

(Allowable voltage fluctuation: +10% to −15%, allowable frequency fluctuation: ±5%)

Required power capacity: 100 VA (for independent drive system)

250 VA (for NC system)

C

o

Control Method

Power regenerative control (120_ current conduction)

Overload Capacity

120% for one minute, 200% for one second

oller

Approx. Mass

lb (kg)

11 (5)

27 (12)

35 (16)

ontro

Di

i

i i h

Width

3.94 (100)

5.91 (150)

7.84 (200)

Co

n

Dimensions in inches
(mm)

*3

Height

13.78 (350)

(mm)

*3

Depth

12.60 (320)

Power Supply AC Reactor Code

No.

X010058

X010059

X010060

X010061

X010062

X010063

X010064

Model CIMR-M5j

*2

CIMR-MR5j

*2

25P5

27P5

2011

2015

2018

2022

2030

Ambient Temperature

0°C to 55°C (32°F to 131°F) (not frozen)

n

Heatsink Intake Air Temperature

0°C to 45°C (32°F to 113°F)

mon

Storage Temperature

*5

−20°C to 60°C (−4°F to 140°F)

C

om

m

Humidity

90% or less (non-condensing)

C

o

Location

Indoor (protected from corrosive gases and dust), elevation: 1000 m (3280 ft) or less

Vibration

9.8 m/s

2

(1G) at 10 to less than 20 Hz, up to 2 m / s

2

(0.2G) at 20 to 50 Hz

Protective Structure

IEC IP00

(Protected so that parts of the human body cannot reach electrically charged parts from the front)

* 1. Rated output power is guaranteed when input voltage is three-phase, 200 V (50/60 Hz), 220 V (50/60 Hz), 230 V (60 Hz). If

input voltage is lower than 200 V, rated output power is not guaranteed.

* 2. A: For stand-alone drive system N: for NC system
* 3. Dimensions of External Heatsink Cooling Type. Refer to 14.1.3 Dimensions for Open Chassis Type.
* 4. An AC reactor is required between Converter and main circuit power supply.
* 5. Temperature during shipping.

14

This manual is related to the following products: