Parameter program example integer type data – Yaskawa MP900 Series Machine Controller New Ladder Editor User Manual
Page 76

1 Ladder Program Instructions
1.3.10 RANGE CHECK Instruction (RCHK)
1-66
Parameter
Program Example
Integer Type Data
Parameter Name
Setting
Input
• Any integer type, double-length integer type and real number
type register
• Any integer type, double-length integer type and real number
type register with subscript
• Subscript register
• Constant
Lower Limit
• Any integer type, double-length integer type and real number
type register
• Any integer type, double-length integer type and real number
type register with subscript
• Subscript register
• Constant
Upper Limit
• Any integer type, double-length integer type and real number
type register
• Any integer type, double-length integer type and real number
type register with subscript
• Subscript register
• Constant
Input (MW00100)
Output (DB000000)
-1000 > MW00100
OFF
-1000 <
= MW00100 <= 1000
ON
MW00100 >1000
OFF