Readout of data, Configuration of the read data – Yaskawa MP900 Series Machine Controller New Ladder Editor User Manual
Page 218

2.2 Trace Functions
2-25
2
Readout of Data
Readout of Data is described in Figure 2.4.
Fig. 2.4 Data Read
The most recent record No. of trace groups are each stored in SW00100 to SW00103.
Configuration of the Read Data
Configuration of the read data is described in Figure 2.5.
Fig. 2.5 Configuration of the Read Data
Table 2.11 Newest Records Number
System Register Number
Data Trace Definition
SW00100
For group 1
SW00101
For group 2
SW00102
For group 3
SW00103
For group 4
SW00104
−
SW00105
−
SW00106
−
SW00107
−
Data Trace Memory
Number of
read records
Old
New
User Register
0
n
Record No.
No. of the head
record to be read
Head address of
the register into
which data is read
Readout
Max. 32512 words
Dat - Adr
1 to 32 words
1 to 32 words
1 to 32 words
Trace data
Old
New
Record 2
Record n
Record 1
ITEM1
ITEM16
•
•
•
•
•
•