Parameter failure occurrence data readout – Yaskawa MP900 Series Machine Controller New Ladder Editor User Manual
Page 220

2.2 Trace Functions
2-27
2
Parameter
Failure Occurrence Data Readout
Failure occurrence data readout is described in Figure 2.6. The readout will always be
started from the most recent record.
Fig. 2.6 Failure Occurrence Data Readout
I/O
Definition
Parameter
Name
I/O
Designation
Setting
Input
Execute
B-VAL
Failure trace readout instruction
Reset
B-VAL
Failure trace buffer reset instruction
Type
I-REG
Type of data read
1: Occurrence data
2: Restoration data
Rec-Size
I-REG
Number of read record
Occurrence data: 1 to 64 Restoration data: 450
Dat-Adr
Address in-
put
Head register address for reading (address of MW or
DW)
Output
Complete
B-VAL
Completion of failure trace read
Error
B-VAL
Occurrence of error
Status
I-REG
Failure trace read execution status
Rec-Size
I-REG
Number of records read
Rec-Len
I-REG
Length of record read
Table 2.12 Failure Trace Reading Execution Status (STATUS)
Name
Bit No.
Remarks
System reserved
bit0 to bit7
No trace definition
bit8
The function will not be executed.
Designated type No. error
bit9
The function will not be executed.
System reserved
bit10
Error in the designated
number of records
bit11
The function will not be executed.
Data storage error
bit12
The function will not be executed.
System reserved
bit13
System reserved
bit14
System reserved
bit15
The function will not be executed.
User Register
Readout
Failure Occurrence Trace Memory
Number of
read records
Old
New
Head address of
the register into
which data is read
Most recent
record