Format parameter – Yaskawa MP900 Series Machine Controller New Ladder Editor User Manual
Page 177

1.8 Table Data Manipulation Instructions
1-167
1
Format
Parameter
* Possible to omit.
Table 1.32 Block Read PI Instruction Parameters
ADR
Type
Symbol
Name
Specifications
I/O
0
L
ROW1
Table element beginning
row number
Beginning row number of the target table element
(1 to 65535)
IN
2
L
COL1
Table element beginning
column number
Beginning column number of the target table ele-
ment (1 to 32767)
IN
4
W
RLEN
Number of row elements
Number of row elements (1 to 32767)
IN
5
W
CLEN
Number of column ele-
ments
Number of column elements (1 to 32767)
IN
Parameter Name
Setting
Table Name
Table name
Read Data
• Register address (except for # and C registers)
• Register address with subscript
Parameter
• Register address
• Register address with subscript
[Output]*
• Any integer type register (except for # and C registers)
• Any integer type register with subscript
• Subscript register
[Status]*
• Any bit type register (except for # and C registers)
• Any bit type register with subscript
Symbol: TBLBR
Full Name: Table Block Read
Category: TABLE
Icon: