Parameter – Yaskawa MP900 Series Machine Controller New Ladder Editor User Manual
Page 233

2 Standard System Function
2.3.2 Inverter Constant Read Function (ICNS-RD)
2-40
Parameter
Note: In the case of an inverter response error, the error codes from the
inverter are indicated in bit0 to bit7.
01H(1): function code error
02H(2): reference No. error
Numbers in ( ) are of decimal expressions.
I/O
Definition
Parameter
Name
I/O
Designation
Setting
Input
Execute
B-VAL
Inverter constant read execution instruction
Abort
B-VAL
Inverter constant read forced interruption instruction
Dev-Typ
I-REG
Type of transmission device
215IF
= 1
MP930
= 4
SVB-01
= 11
Cir-No
I-REG
Line No.
215IF
= 1, 2
MP930
= 1
SVB-01
= 1 to 16
St-No
I-REG
Slave station No.
215IF
= 1 to 64
MP930
= 1 to 14
SVB-01
= 1 to 14
Ch-No
I-REG
Transmission buffer channel No.
215IF
= 1 to 3
MP930
= 1
SVB-01
= 1 to 8
Cns-Typ
I-REG
Type of inverter constant
0
= direct designation of reference No. 1 = An. 2 = Bn, 3 = Cn,
4
= Dn, 5 = En, 6 = Fn, 7 = Hn, 8 = Ln, 9 = On, 10 = Tn
Cns-No
I-REG
Inverter constant No. (1 to 99)
The upper limit will differ according to the type of inverter.
If Cns-Typ
= 0, designate the reference No.
Cns-Size
I-REG
Number of inverter constants (number of data to be read) 1 to 100
Dat-Adr
Address in-
put
Register address of read-out destination (address of MW or DW)
Output
Busy
B-VAL
Inverter constants are being read.
Complete
B-VAL
The reading of inverter constants has been completed.
Error
B-VAL
Occurrence of error
Status
I-REG
Inverter constant read execution status
Table 2.16 Configuration of Inverter Constant Read Execution Status (STASTUS)
Name
Bit No.
Remarks
System reserved
bit0 to bit7
Execution sequence error
bit8
The function will not be executed.
Transmission parameter
error
bit9
The function will not be executed.
Designated type error
bit10
The function will not be executed.
Designated No. error
bit11
The function will not be executed.
Error in number (amount)
of the designated data
bit12
The function will not be executed.
Transmission error
bit13
The function will not be executed.
Inverter response error
bit14
The function will not be executed.
Address input error
bit15
The function will not be executed.