2 trace functions, 1 trace function (trace), Outline – Yaskawa MP900 Series Machine Controller New Ladder Editor User Manual
Page 215: Format parameter

2 Standard System Function
2.2.1 Trace Function (TRACE)
2-22
2.2 Trace Functions
2.2.1 Trace Function (TRACE)
Outline
Performs execution control of the traces of the trace data designated by the trace group No.
The trace is defined as "Data Trace Definition" screen.
• Tracing is executed when the trace execution command (Execute) is set to ON.
• The trace counter is reset when the trace reset command (Reset) is set to ON.
The trace end (Trc-End) output is also reset at this time.
• The trace end (Trc-End) output is set to ON when the trace execution count becomes
equal to the set count (set as Trace Definition).
Format
Parameter
I/O
Definition
Parameter
Name
I/O
Designation
Setting
Input
Execute
B-VAL
Trace execution command
Rese
t
B-VAL
Trace reset command
Group-No
I-REG
Designation of the trace group
Output
Trc-End
B-VAL
End of Trace
Error
B-VAL
Occurrence of error
Status
I-REG
Trace execution status
Symbol: TRACE
Full Name: Trace
Category: SYSTEM
Icon: