2 Standard System Function

2.2.2 Data Trace Read Function (DTRC-RD)

2-24

„

Parameter

I/O

Definition

Parameter

Name

I/O

Designation

Setting

Input

Execute

B-VAL

Designation of the execution of data trace read

Group-No

I-REG

Designation of the data trace group No. (1 to 4)

Rec-No

I-REG

Designation of the head record No. for readout (0 to
maximum number of records-1)

Rec-Size

I-REG

Designation of the number of records requested for
readout (1 to maximum number of records)

Select

I-REG

Item to be read out (0001H to FFFFH)
Bits 0 to F correspond to data designations 1 to 16 of
the trace definition.

Dat-Adr

Address in-
put

Designation of the No. of the head register for readout
(address of MW or DW)

Output

Complete

B-VAL

Completion of trace read

Error

B-VAL

Occurrence of error

Status

I-REG

Data trace read execution status

Rec-Size

I-REG

Number of records read

Rec-Len

I-REG

Length (in words) of 1 record that is read

Table 2.10 Configuration of the Data Trace Read Execution Status (STATUS)

Name

Bit No.

Note

System reserved

bit0 to bit7

No trace definition

bit8

The function is not executed.

Group No. error

bit9

The function is not executed.

Designated record No.
error

bit10

Error in the designated
number of records read

bit11

The function is not executed.

Data storage error

bit12

The function is not executed.

System reserved

bit13

System reserved

bit14

Address input error

bit15

The function is not executed.