rs

Reset status display, Q
parameters and tool
data

MP7300
Reset them all when a program is selected: 0
Reset them all when a program is selected and with M02, M30, END PGM: 1
Reset only status display and tool data when a program is selected: 2
Reset only status display and tool data when a program is selected and with M02, M30, END
PGM: 3
Reset status display and Q parameters when a program is selected: 4
Reset status display and Q parameters when a program is selected and with M02, M30, END
PGM: 5
Reset status display when a program is selected: 6
Reset status display when a program is selected and with M02, M30, END PGM: 7

Graphic display mode

MP7310
Projection in three planes according to ISO 6433, projection method 1: +1
Projection in three planes according to ISO 6433, projection method 2: +1
Do not rotate coordinate for graphic display: +0
Rotate coordinate system for graphic display by 90°: +2
Display new BLK FORM in Cycle 7 DATUM SHIFT referenced to the old datum: +0
Display new BLK FORM in Cycle 7 DATUM SHIFT referenced to the new datum: +4
Do not show cursor position during projection in three planes: +0
Show cursor position during projection in three planes: +8

Graphic simulation
without programmed
tool axis: Tool radius

MP7315
0
to 99 999.9999 [mm]

Graphic simulation
without programmed
tool axis: Penetration
depth

MP7316
0
to 99 999.9999 [mm]

Graphic simulation
without programmed
tool axis: M function
for start

MP7317.0
0
to 88 (0: Function inactive)

Graphic simulation
without programmed
tool axis: M function
for end

MP7317.1
0
to 88 (0: Function inactive)

Screen saver

Enter the time after
which the TNC should
start the screen saver

MP7392
0
to 99 [min] (0: Function inactive)