7 checking and changing q parameters, Procedure – HEIDENHAIN TNC 426 (280 476) User Manual
Page 393

366
10 Programming: Q Parameters
1
0
.7 Chec
king and c
h
anging Q par
a
met
e
rs
10.7 Checking and changing Q
parameters
Procedure
During a program run or test run, you can check or change Q
parameters if necessary.
7
7
7
7
If you are in a program run, interrupt it (for example by pressing the
machine STOP button and the INTERNAL STOP soft key). If you are
doing a test run, interrupt it.
7
7
7
7
To call the Q parameter functions, press the Q key.
7
7
7
7
Enter the Q parameter number and press the ENT key.
The TNC displays the current value of the Q
parameter in the dialog line.
7
7
7
7
If you wish to change the value, enter a new value,
confirm it with the ENT key and conclude your entry
with the END key.
7
7
7
7
To leave the value unchanged, terminate the dialog
with the END key.