beautypg.com

2 t ool d a ta – HEIDENHAIN TNC 426 (280 476) User Manual

Page 129

background image

102

5 Programming: Tools

5.2 T

ool D

a

ta

Tool table: Tool data required for automatic tool measurement

TIME2

Maximum tool life in minutes during TOOL CALL: If the current
tool age exceeds this value, the TNC changes the tool during the
next TOOL CALL (see also CUR.TIME).

Maximum tool age for TOOL CALL?

CUR.TIME

Time in minutes the tool has been in use: The TNC automatically
counts the current tool age. A starting value can be entered for
used tools.

Current tool life?

DOC

Comment on tool (up to 16 characters)

Tool description?

PLC

Information on this tool that is to be sent to the PLC

PLC status?

PLC VAL

Value of this tool that is to be sent to the PLC

PLC value?

Abbr.

Input

Dialog

For a description of the cycles governing automatic tool
measurement, see the new Touch Probe Cycles Manual,
Chapter 4.

Abbr.

Input

Dialog

CUT

Number of teeth (20 teeth maximum)

Number of teeth ?

LTOL

Permissible deviation from tool length L for wear detection. If the
entered value is exceeded, the TNC locks the tool (status L). Input
range: 0 to 0.9999 mm

Wear tolerance: length ?

RTOL

Permissible deviation from tool radius R for wear detection. If the
entered value is exceeded, the TNC locks the tool (status L). Input
range: 0 to 0.9999 mm

Wear tolerance: radius ?

DIRECT.

Cutting direction of the tool for measuring the tool during rotation

Cutting direction (M3 = –) ?

TT:R-OFFS

For tool length measurement: tool offset between stylus center
and tool center. Preset value: Tool radius R (NO ENT means R).

Tool offset: radius ?

TT:L-OFFS

Tool radius measurement: tool offset in addition to MP6530
between upper surface of stylus and lower surface of tool. Preset
value: 0

Tool offset: length ?

LBREAK

Permissible deviation from tool length L for breakage detection. If
the entered value is exceeded, the TNC locks the tool (status L).
Input range: 0 to 0.9999 mm

Breakage tolerance: length ?

RBREAK

Permissible deviation from tool radius R for breakage detection. If
the entered value is exceeded, the TNC locks the tool (status L).
Input range: 0 to 0.9999 mm

Breakage tolerance: radius ?

This manual is related to the following products: