beautypg.com

HEIDENHAIN TNC 306 Service Manual User Manual

Page 97

background image

SERVICE MANUAL TNC 306/360

Page 90

HEIDENHAIN Service

19.1.5 Determining Data for the Supplementary Operating
Modes:

If the "PROCESSOR BOARD" assembly or the complete "LOGIC UNIT" are to be
exchanged, or if a software exchange is to be carried out, the preset values and the current
entry values of the auxiliary operating modes should be determined, so that they can be re-
entered after the exchange.

TNC Dialog Display

Press
Key

Remarks

MEMORY TEST

-

POWER INTERRUPTED

CE

RELAY EXT. DC VOLTAGE MISSING

Switch on control voltage

TRAVERSE REFERENCE POINTS

<1. AXIS>
<2. AXIS>

MOD

Do not yet traverse the reference points!

FREE MEMORY = XXXXX

PROGRAM INPUT:

XXXXXXXXXX
0 HEIDENHAIN
0 ISO

Note down the format in which the NC-
programs have been entered

CHANGE MM/INCH

POSITION DISPLAY

0

0

0

0

0

ACTL

REF

LAG

NOML

DIST

Note down the current setting for the position
display, then switch to ACTL by pressing

ENT

ACTL X

.

Note down the preset values

ACTL Y

.

(Do not forget the algebraic signs)

ACTL Z

.

ACTL IV

.

POSITION DISPLAY LARGE/SMALL

BAUD-RATE =

Note down the Baud rate

RS232-C INTERFACE =

ME 0
FE

0

EXT 0

Note down the operating mode of the
RS232-C interface