Page 60
HEIDENHAIN Service
15.1.1 Machine Parameter Input
OPERATION PARAMETERS ERASED
If this error message is displayed load the machine parameters as follows:
Press key
Function
CE
Clear
OPERATION PARAMETERS ERASED
CE
Clear
PLC: PROGRAM MEMORY ERASED
MOD
Configure the interface as described in section 14.2.
END
EXT
Prepare TNC for data input
Enter the program number under which the machine parameters
are stored.
ENT
Start data transfer
When the data transfer is finished, the following dialog
EXTERNAL DATA INPUT
1) is cleared.
END
Exit the machine parameter mode.
CE
Clear
POWER INTERRUPTED
1) If the error message
ENTRY VALUE INCORRECT
is generated during data input, this can be due to the following reasons:
- The TNC requires more machine parameters than are stored on the external data
medium (e.g. after a software exchange).
- At least one machine parameter has a non-permissible value.
- Press
ENT
to continue data transfer and enter the missing or incorrect parameter
values manually after the transfer.
Contact your machine tool manufacturer regarding these machine parameters.