beautypg.com

5 printer connection – HEIDENHAIN TNC 306 Service Manual User Manual

Page 63

background image

SERVICE MANUAL TNC 306/360

Page 56

HEIDENHAIN Service

MP

Function

Entry Value

5010.5

EOT or substitute character. Is transferred at
the end of data transfer.

EOT:
4

5030

7 data bits, transfer stop by DC3,
parity bit (even parity), 1 stop bit

168

5030

Transfer blockwise

1

Determination of the input value:

Example: Program end:

ETX

BINARY code

00000011 (low byte)

Program start:

STX

BINARY code

00000010 (high byte)

Bit 0 - 7 (low byte)

7

6

5

4

3

2

1

0

Significance

128

64

32

16

8

4

2

1

Enter 0 or 1

0

0

0

0

0

0

1

1

Bit 8 - 15 (high byte)

15

14

13

12

11

10

9

8

Significance

32 768 16 384

8 192

4 096

2 048

10 24

512

256

Enter 0 or 1

0

0

0

0

0

0

1

0

Determine input value:

1
2

+ 512

--------

515

The input value for the machine parameter MP 5010.0 is 515.

14.5 Printer Connection

For most printers we recommend simplified wiring (see section 14.3).