SERVICE MANUAL TNC 306/360

Page 44

HEIDENHAIN Service

If the VDU remains dark after the test button was pressed, the VDU is defective and must
be exchanged.
If however, the highlighted field appears, the processor board of the LOGIC UNIT is
probably defective.
In addition, the control signals for the VISUAL DISPLAY UNIT can be checked with an
oscilloscope.

Procedure:
Connect the measuring adaptor between the VDU and connector X9 of the LE.
Measure the signals at the corresponding pins and compare the results to the following
diagrams.

2V/DIV

H-SYNC PIN 10

20 µs/DIV

2V/DIV

V-SYNC PIN 9

5 ms/DIV

2V/DIV

VIDEO PIN 13

5 ms/DIV

Note:
With the VIDEO diagram (pin 13) a deviation in the time axis can occur, depending on the
image being displayed.
Moreover, the amplitude (video) doubles, if:
- the VDU is disconnected

or

- the external test button is pressed.