beautypg.com

HEIDENHAIN TNC 306 Service Manual User Manual

Page 38

background image

SERVICE MANUAL TNC 306/360

Page 34

HEIDENHAIN Service

8.4.2 Measuring Points on the Power Supply Board

(for Power Supply Units without Connector X2)

Voltage Value Table

Measuring
Point on the
Power
Supply
Board

Reference
Point on the
Power
Supply
Board

Output

UNOM [V]

UMIN [V]

UMAX [V]

INOM [A]

LH 22

LH 20

LH 18

LH 14

LH 10

LH 2

LH1

LH24

LH 24

LH 24

LH 24

LH 24

LH4

LH3

+ 5V (UP)

+ 12V

+ 15V

- 15V

UBATT

+ 12V BE

+ 5V* 1 1)

+5.05

+ 12

+ 15.0

- 15.0

+ 4.5

+ 12.3

+ 5

+ 5.00

+ 11.4

+ 14.4

- 14.4

+ 3.9

+ 12

+4.75

+ 5.10

+ 12.6

+ 15.6

- 15.6

-

+ 12.6

+ 5.25

2.5

0.1

0.15

0.08

ca. 20 µA

1.3

0.3

1) potential-free
reset ULmax = 0.4V, UHmin = 3.9V

This manual is related to the following products: