beautypg.com

5 offset adjustment, 1220. (see section 16.5) – HEIDENHAIN TNC 306 Service Manual User Manual

Page 81

background image

SERVICE MANUAL TNC 306/360

Page 74

HEIDENHAIN Service

16.5 Offset Adjustment

16.5.1 Offset Adjustment with Code Number

Press key

Function

MOD

Activate auxiliary mode "MOD"

or

Press key repeatedly , until the dialog CODE NUMBER =
appears

7

5

3

6

8

Enter code number

The offset values are displayed individually for each axis in converter increments
(1 converter increment = 0.61 mV).

NO

ENT

ENT

The offset values are transferred to the offset memory and
compensated.

The offset memory is erased and no compensation takes
place.

*

Only the current offset is compensated by means of the code number.
Subsequent offset modifications are not compensated.

16.5.2 Automatic Cyclic Offset Adjustment

In the machine parameter MP1220 the cycle time (unit [s]) is determined, after which an
offset is compensated by one converter increment (0.61 mV). To switch off the automatic
offset adjustment, enter the value 0 in the machine parameter MP1220.

*

Note:
If an offset voltage of 100 mV is reached with automatic offset adjustment, the
control switches itself off, generating the error message "GROSS POSITIONING
ERROR E".

This manual is related to the following products: